Report Icon

Incident Report – 12/23/2022
0 N 36th St, Seattle, WA 98103

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On December 23, 2022, Seattle Fire Department responded to a fire incident at 0 N 36th St, Seattle, WA 98103, a 1-or-2 family dwelling.

The alarm was received on 12/23/2022 at 11:43 PM, 11 suppression personnel arrived on 12/23/2022 at 11:52 PM, and the last unit was cleared on 12/24/2022 at 12:55 AM. The time to arrive was 9 minutes and the total incident time was 1 hour, 12 minutes.

The following actions were taken during the incident: fire/other, salvage and overhaul, and ventilate.

Sponsored

Location


Type Street address
Address 0 N 36th St, Seattle, WA 98103
County King County
State WA
City Seattle
Zip Code 98103
Property Use 1 or 2 family dwelling

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 9 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 1 hour, 12 minutes

Response


Incident Type Building fires
Mutual Aid Given/Received None
Resources Include Mutual Aid No

Personnel


Support Personnel 11
EMS Personnel 0
Other Personnel 0

Fire Department


Name Seattle Fire Department
Department Type Career
Address 301 2ND AVE S
Seattle, WA 98104-2618
Phone (206) 386-1400
Website https://www.seattle.gov/fire/

Actions Taken


First Action Taken Fire, other
Second Action Taken Salvage & overhaul
Third Action Taken Ventilate

Losses *


Property Loss $5,000
Contents Loss $0
Property Value $5,000
Contents Value $0
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key WA_17M15_12232022_154546_0
State Washington
Fire Department ID 17M15
Incident Date 12/23/2022
Incident Number 154546
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Cause


General Cause Electrical
Main Fire Cause Electrical Malfunction
Priority Cause Electrical Dist

Ignition


Area of Origin Interior stairway or ramp
Heat Source Arcing
Item First Ignited Multiple items first ignited
Cause of Ignition Cause undetermined after investigation
Factor Contributing To Ignition Unspecified short-circuit arc

Spread


No Flame Spread/Same As First/Unknown No

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status Under construction
Building Height: Stories Above Grade 3
Building Height: Stories Below Grade 0
Total Square Feet 900 sqft

Number of Stories With Damage


Story of Fire Origin 2
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Acres Burned 0
Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Undetermined

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Portable
Sponsored