Report Icon

Incident Report – 07/15/2019
10 Outer Dr, Silver Bay, MN 55614

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On July 15, 2019, Silver Bay Fire Department responded to a fire incident at 10 Outer Dr, Silver Bay, MN 55614, an industrial/utility/defense/agriculture/mining property.

The alarm was received at 4:05 PM, 3 suppression personnel arrived at 4:15 PM, and the last unit was cleared at 4:44 PM. The time to arrive was 10 minutes and the total incident time was 39 minutes.

The following action was taken during the incident: fire/other.

Sponsored

Location


Type Street address
Address 10 Outer Dr, Silver Bay, MN 55614
County Lake County
State MN
City Silver Bay
Zip Code 55614
Property Use Utility, defense, agriculture, mining, other
Detector Alerted Occupants Detector alerted occupants
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 10 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 39 minutes

Response


Incident Type Fires in structures other than in a building
Department Station FD
Mutual Aid Given/Received Mutual aid received
Resources Include Mutual Aid No
Alarms 1

Personnel


Support Personnel 3
EMS Personnel 0
Other Personnel 0

Fire Department


Name Silver Bay Fire Department
Department Type Volunteer
Address Banks Blvd
Silver Bay, MN 55614
Phone (218) 226-0059

Actions Taken


First Action Taken Fire, other

Metadata


Incident Key MN_38103_07152019_19066_0
State Minnesota
Fire Department ID 38103
Incident Date 07/15/2019
Incident Number 19066
Exposure Number 0
NFIRS Version 5.0

Fire Report

Cause


General Cause Equipment
Main Fire Cause Equipment Misoperation, Failure
Priority Cause Equipment Failure, Malfunction

Ignition


Area of Origin Corridor, mall
Heat Source Spark, ember or flame from operating equipment
Item First Ignited Conveyor belt, drive belt, V-belt
Confined To Origin Fire Spread was Confined to Object of Origin
Type of Material Rubber, excluding synthetic rubbers
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Mechanical failure, malfunction, other

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential Yes
Number of Buildings Involved 1
Structure Type Open structure
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 1

Number of Stories With Damage


Story of Fire Origin 1

Acres


Less Than One Acre No

Automatic Extinguishing System


AES Presence Present
AES Type Undetermined
AES Operation Undetermined

Detector


Detector Presence Detectors Present
Detector Type Combination smoke - heat
Detector Power Hardwire Only
Detector Operation Operated
Detector Effectiveness Alerted Occupants
Sponsored