On August 21, 2022, City of Red Bluff Fire Department responded to a fire incident at 10 Root Ave, Red Bluff, CA 96080, an outbuilding/shed.

The alarm was received on 08/21/2022 at 4:44 PM, 31 suppression personnel arrived on 08/21/2022 at 4:49 PM, the incident was controlled on 08/21/2022 at 11:00 PM, and the last unit was cleared on 08/22/2022 at 12:30 AM. The time to arrive was 5 minutes, the time to control the incident was 6 hours, 11 minutes, and the total incident time was 7 hours, 46 minutes.

The following actions were taken during the incident: fire/other and salvage and overhaul.

Sponsored

Location


Type Street address
Address 10 Root Ave, Red Bluff, CA 96080
County Tehama County
State CA
City Red Bluff
Zip Code 96080
Property Use Outbuilding or shed
Detector Alerted Occupants Unknown
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 5 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 6 hours, 11 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 7 hours, 46 minutes

Response


Incident Type Building fires
Department Station ST1
Mutual Aid Given/Received Automatic aid received
Resources Include Mutual Aid No

Personnel


Support Personnel 31
EMS Personnel 0
Other Personnel 0

Fire Department


Name City of Red Bluff Fire Department
Department Type Mostly career
Address 555 Washington St
Red Bluff, CA 96080
Phone (530) 527-1126
Website https://www.rbfd.org/

Actions Taken


First Action Taken Fire, other
Second Action Taken Salvage & overhaul

Losses *


Property Loss $4,000
Contents Loss $0
Property Value $10,000
Contents Value $0
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key CA_52020_08212022_2911_6
State California
Fire Department ID 52020
Incident Date 08/21/2022
Incident Number 2911
Exposure Number 6
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Cause


General Cause Exposure
Main Fire Cause Exposure

Ignition


Area of Origin Wall surface: exterior
Heat Source Radiated heat from another fire
Item First Ignited Exterior wall covering or finish
Type of Material Sawn wood, including all finished lumber
Cause of Ignition Cause, other
Factor Contributing To Ignition Exposure fire

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential Yes
Number of Buildings Involved 0
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Total Square Feet 250 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present