Incident Report – 10/14/1989 100 S 200 E, Enterprise, UT 84725
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On October 14, 1989, Enterprise Fire Department responded to a fire incident at 100 S 200 E, Enterprise, UT 84725, a residential use, 1-or-2 family dwelling.
The alarm was received at 2:00 PM and 6 suppression personnel arrived at 2:05 PM. The time to arrive was 5 minutes.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Address | 100 S 200 E, Enterprise, UT 84725 |
| County | Washington County |
| State | UT |
| City | Enterprise |
| Zip Code | 84725 |
| Mixed Use | Residential use |
| Property Use | 1 or 2 family dwelling |
| Census Tract | 000000 |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 5 minutes
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | None |
| Shift | 0 |
| Alarms | 1 |
| District | 000 |
Personnel
| Support Personnel | 6 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | Enterprise Fire Department |
| Department Type | Mostly volunteer |
| Address | 246 E 200TH S Enterprise, UT 84725 |
| Phone | (435) 878-2314 |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | UT_53002_101489_890001_00 |
| State | Utah |
| Fire Department ID | 53002 |
| Incident Date | 10/14/1989 |
| Incident Number | 890001 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Electrical Dist |
Legacy Fields
| Estimated Dollar Loss | 0 |
| Day of Week | Saturday |
| Time In Service | 16:30 |
| Zip Code | 84725 |
| Method of Alarm | Coded signal municipal fire alarm system |
| Type of Situation Found | Structure fire |
| Type Action Taken | Extinguishment |
| Number of Aerial Apparatus | 0 |
| Complex | Dwelling complex (one-and two-family) |
| Fixed Property Use | One-family dwelling: year-round use |
| Mobile Property type | Mobile Property Type not applicable |
| Area of Fire Origin | Laundry room, area |
| Level of Fire Origin | Grade level to 9 feet above grade |
| Number of Stories | 1 |
| Equipment Involved in Ignition | Cord, plug |
| Form of Heat of Ignition | Short circuit arc from defective, worn insulation |
| Type of Material Ignited | Cotton, rayon, cotton fabric, finished goods |
| Form of Material Ignited | Curtain, blind, drapery, tapestry |
| Ignition Factor | Mechanical Failure, Malfunction; insufficient information available to classify further |
| Construction Type | Unprotected wood frame not qualifying for 7 |
| Extent of Flame Damage | Confined to part of room or area of origin |
| Extent of Smoke Damage | Extended beyond structure of origin |
| Form of Material Generating Most Smoke | Type of Material not applicable |
| Detector Performance | Performance of Fire Detection Equipment undetermined or not reported |
| Sprinkler Performance | No equipment present in room or space of fire origin |
| Avenue of Smoke Travel | Most Significant Avenue of Smoke Travel not classified above |
| Method of Extinguishment | Preconnected hose line(s) with water from hydrant, draft, standpipe |
| Property Damage Classification | Undertermined |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | ONE- AND TWO-FAMILY DWELLING |
Fire Report
Ignition
| Heat Source | Arcing |
| Item First Ignited | Curtains, blinds, drapery, tapestry |
| Type of Material | Fabric, fiber, cotton, blends, rayon, wool |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Short circuit arc from defective, worn insulation |
Structure
| Number of Residential Units | 1 |
Number of Stories With Damage
| Story of Fire Origin | 26 |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Mobile Property Involved
| Mobile Property Type | Tank truck - compressed gas or LP-gas |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Portable |
Sponsored