On August 5, 1998, Village of Oakwood Fire Department responded to a fire incident at 103 E Harmon St, Oakwood, OH 45873, a residential use, 1-or-2 family dwelling.

The alarm was received at 8:58 PM and 9 suppression personnel arrived at 9:04 PM. The time to arrive was 6 minutes.

The following action was taken during the incident: standby.

Sponsored

Location


Address 103 E Harmon St, Oakwood, OH 45873
County Paulding County
State OH
City Oakwood
Zip Code 45873
Mixed Use Residential use
Property Use 1 or 2 family dwelling
Census Tract 000000
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 6 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received None
Alarms 1

Personnel


Support Personnel 9
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name Village of Oakwood Fire Department
Department Type Volunteer
Address 108 Coder St
Oakwood, OH 45873-0457
Phone (419) 594-3381

Actions Taken


First Action Taken Standby

Metadata


Incident Key OH_63015_080598_098025_00
State Ohio
Fire Department ID 63015
Incident Date 08/05/1998
Incident Number 098025
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Special Equip

Legacy Fields


Estimated Dollar Loss 125
Day of Week Wednesday
Time In Service 21:50
Zip Code 45873
Method of Alarm Telephone direct to fire department
Type of Situation Found Structure fire
Type Action Taken Standby
Number of Aerial Apparatus 0
Complex Dwelling complex (one-and two-family)
Fixed Property Use One-family dwelling: year-round use
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Heating equipment room or area, water heater area
Level of Fire Origin Grade level to 9 feet above grade
Number of Stories 1
Equipment Involved in Ignition Separate pump, compressor
Form of Heat of Ignition Unspecified short circuit arc
Type of Material Ignited Plastic; insufficient information available to classify further
Form of Material Ignited Electrical wire, cable insulation
Ignition Factor Short circuit, ground fault
Construction Type Unprotected wood frame not qualifying for 7
Extent of Flame Damage Confined to the object of origin
Extent of Smoke Damage Confined to the object of origin
Form of Material Generating Most Smoke Type of Material not applicable
Detector Performance Performance of Fire Detection Equipment undetermined or not reported
Sprinkler Performance No equipment present in room or space of fire origin
Avenue of Smoke Travel No significant avenue of smoke travel
Method of Extinguishment Self-extinguished
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING

Fire Report

Ignition


Heat Source Arcing
Item First Ignited Electrical wire, cable insulation
Type of Material Plastic
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Unspecified short-circuit arc

Structure


Number of Residential Units 1

Number of Stories With Damage


Story of Fire Origin 62

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Equipment


Equipment Power Electrical, other
Equipment Portability Unknown
Sponsored