Report Icon

Incident Report – 03/16/2015
103 Progress Way, Avilla, IN 46710

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On March 16, 2015, Avilla Fire Department responded to a fire incident at 103 Progress Way, Avilla, IN 46710, a manufacturing/processing facility.

The alarm was received at 1:19 PM, 6 suppression personnel arrived at 1:28 PM, the incident was controlled at 1:48 PM, and the last unit was cleared at 2:23 PM. The time to arrive was 9 minutes, the time to control the incident was 20 minutes, and the total incident time was 1 hour, 4 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Type Street address
Address 103 Progress Way, Avilla, IN 46710
County Noble County
State IN
City Avilla
Zip Code 46710
Property Use Manufacturing, processing
Census Tract AV

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 9 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 20 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 1 hour, 4 minutes

Response


Incident Type Building fires
Department Station 30
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Alarms 0
District 01

Personnel


Support Personnel 6
EMS Personnel 0
Other Personnel 0

Fire Department


Name Avilla Fire Department
Department Type Volunteer
Address 204 S Main St
Avilla, IN 46710-0440
Phone (260) 897-3295
Website https://avillafire.com/

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key IN_57002_03162015_0000036_0
State Indiana
Fire Department ID 57002
Incident Date 03/16/2015
Incident Number 0000036
Exposure Number 0
NFIRS Version 5.0

Fire Report

Ignition


Area of Origin Duct: hvac, cable, exhaust, heating, or AC
Heat Source Spark, ember or flame from operating equipment
Item First Ignited Insulation within structural area
Confined To Origin Fire Spread was Confined to Object of Origin
Type of Material Multiple types of material
Cause of Ignition Unintentional
Factor Contributing To Ignition Failure to clean

On-Site Materials


On-Site Material Construction, machinery, metals, other

Spread


No Flame Spread/Same As First/Unknown No

Structure


Not Residential Yes
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 2
Building Height: Stories Below Grade 0
Total Square Feet 40000 sqft
Number of Sprinklers Operating 0

Number of Stories With Damage


Story of Fire Origin 2
Number of Stories with Damage: Minor 1
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Acres Burned 0
Less Than One Acre No

Automatic Extinguishing System


AES Presence Present
AES Type Wet pipe sprinkler
AES Operation Fire too small to Operate
AES Failure Reason Reason system not effective, other

Suppression Factors


Suppression Factor Metal truss construction
Suppression Factor Fire supression factor, other

Detector


Detector Presence Detectors Present
Detector Type Other
Detector Operation Fire too small to operate

Equipment


Equipment Power Electrical, other
Equipment Portability Stationary
Sponsored