Incident Report – 11/01/1993 1066 N Main St, Providence, RI 02904
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On November 1, 1993, Providence Fire Department responded to a fire incident at 1066 N Main St, Providence, RI 02904, a manufacturing/processing facility.
The alarm was received at 3:35 AM and 56 suppression personnel arrived at 3:36 AM. The time to arrive was 1 minute.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Address | 1066 N Main St, Providence, RI 02904 |
| County | Providence County |
| State | RI |
| City | Providence |
| Zip Code | 02904 |
| Property Use | Manufacturing, processing |
| Census Tract | 003300 |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 1 minute
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | None |
| Shift | 4 |
| Alarms | 3 |
| District | 002 |
Personnel
| Support Personnel | 56 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | Providence Fire Department |
| Department Type | Career |
| Address | 325 Washington St Providence, RI 02903 |
| Phone | (401) 243-6060 |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | RI_02800_110193_030877_01 |
| State | Rhode Island |
| Fire Department ID | 02800 |
| Incident Date | 11/01/1993 |
| Incident Number | 030877 |
| Exposure Number | 01 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Exposure |
Legacy Fields
| Estimated Dollar Loss | 10,000 |
| Day of Week | Monday |
| Zip Code | 02904 |
| Method of Alarm | Telephone direct to fire department |
| Type of Situation Found | Structure fire |
| Type Action Taken | Extinguishment |
| Number of Aerial Apparatus | 5 |
| Complex | No complex |
| Fixed Property Use | Wearing apparel manufacture, excluding footwear |
| Mobile Property type | Mobile Property Type not applicable |
| Area of Fire Origin | Exterior roof surface |
| Number of Stories | 1 |
| Equipment Involved in Ignition | No equipment involved |
| Form of Heat of Ignition | Heat from direct flame, convection currents |
| Type of Material Ignited | Asphalt treated material |
| Form of Material Ignited | Exterior roof covering, surface, finish |
| Ignition Factor | Property too close to |
| Construction Type | Unprotected ordinary, not qualifying 5 |
| Extent of Flame Damage | Confined to part of room or area of origin |
| Extent of Smoke Damage | Confined to floor of origin |
| Form of Material Generating Most Smoke | Structural member, framing |
| Detector Performance | No detectors present |
| Sprinkler Performance | Equipment present but fire too small to require operation |
| Type of Material Generating Most Smoke | Sawn wood |
| Avenue of Smoke Travel | Corridor |
| Property Damage Classification | 10,000-24,999 dollars |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | MANUFACTURING PROPERTY: UNCLASSIFIED |
Fire Report
Ignition
| Heat Source | Heat from direct flame, convection currents |
| Item First Ignited | Exterior roof covering or finish |
| Type of Material | Asphalt treated material |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Exposure fire |
Structure
| Number of Sprinklers Operating | 0 |
Number of Stories With Damage
| Story of Fire Origin | 77 |
Automatic Extinguishing System
| AES Presence | Present |
| AES Type | Undetermined |
| AES Operation | Fire too small to Operate |
Detector
| Detector Presence | None Present |