Summary


On June 3, 2015, Hancock Volunteer Fire Department responded to a fire incident at 107 Potter Mountain Rd, Hancock, MA 01237, a non-mixed use, outbuilding/shed.

The alarm was received at 8:39 PM, 24 suppression, 2 EMS, and 2 other personnel arrived at 8:48 PM, the incident was controlled at 10:00 PM, and the last unit was cleared at 11:34 PM. The time to arrive was 9 minutes, the time to control the incident was 1 hour, 12 minutes, and the total incident time was 55 minutes.

The following actions were taken during the incident: extinguish and salvage and overhaul.

Sponsored

Location


Type Street address
Address 107 Potter Mountain Rd, Hancock, MA 01237
County Berkshire County
State MA
City HANCOCK
Zip Code 01237
Mixed Use Not mixed use
Property Use Outbuilding or shed
Detector Alerted Occupants Detector did not alert occupants

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 9 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 1 hour, 12 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 55 minutes

Response


Incident Type Building fires
Mutual Aid Given/Received Mutual aid received
Resources Include Mutual Aid Yes

Personnel


Support Personnel 24
EMS Personnel 2
Other Personnel 2

Fire Department


Name Hancock Volunteer Fire Department
Department Type Volunteer
Address 3276 Hancock Rd
Hancock, MA 01237
Phone (413) 738-5446

Actions Taken


First Action Taken Extinguish
Second Action Taken Salvage & overhaul

Losses *


Property Loss $20,000
Contents Loss $10,000
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key MA_03121_06032015_0000052_0
State Massachusetts
Fire Department ID 03121
Incident Date 06/03/2015
Incident Number 0000052
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Ignition


Area of Origin Wall assembly
Heat Source Heat from powered equipment, other
Item First Ignited Structural member or framing
Type of Material Sawn wood, including all finished lumber
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Electrical failure, malfunction, other
Factor Contributing To Ignition Unspecified short-circuit arc

Spread


No Flame Spread/Same As First/Unknown Yes
Item Contributing Most To Spread Structural member or framing
Type Material Contributing Most To Spread Sawn wood, including all finished lumber

Structure


Not Residential No
Structure Type Enclosed building
Structure Status Vacant and secured
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Building Length 30 ft
Building Width 10 ft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 1
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary
Sponsored