On November 21, 1996, Olney Fire Department responded to a fire incident at 108 E Main St, Calhoun, IL 62419, a 1-or-2 family dwelling.

The alarm was received at 7:04 PM and 20 suppression personnel arrived at 7:15 PM. The time to arrive was 11 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address 108 E Main St, Calhoun, IL 62419
County Richland County
State IL
City Calhoun
Zip Code 62419
Property Use 1 or 2 family dwelling
Census Tract 000000
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 11 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received None
Shift 2
Alarms 2
District 000

Personnel


Support Personnel 20
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name Olney Fire Department
Department Type Mostly volunteer
Address 501 N Walnut St
Olney, IL 62450-2041
Phone (618) 392-6341
Website https://www.olneyfd.com/

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key IL_RB142_112196_000255_00
State Illinois
Fire Department ID RB142
Incident Date 11/21/1996
Incident Number 000255
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Heating

Legacy Fields


Estimated Dollar Loss 500
Day of Week Thursday
Time In Service 20:27
Zip Code 62419
Method of Alarm Radio
Type of Situation Found Structure fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 0
Complex No complex
Fixed Property Use One-family dwelling: year-round use
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Lounge area
Level of Fire Origin Grade level to 9 feet above grade
Number of Stories 1
Equipment Involved in Ignition Chimney, gas vent flue
Form of Heat of Ignition Spark, ember, flame escaping from solid fueled equipment
Type of Material Ignited Adhesive, resin, tar
Form of Material Ignited Rubbish, trash, waste
Ignition Factor Part failure, leak, break
Construction Type Unprotected wood frame not qualifying for 7
Extent of Flame Damage Confined to part of room or area of origin
Extent of Smoke Damage Confined to room of origin
Form of Material Generating Most Smoke Structural member, framing
Detector Performance No detectors present
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Sawn wood
Avenue of Smoke Travel Corridor
Method of Extinguishment Preconnected hose line(s) with water carried in apparatus tanks
Property Damage Classification 100-999 dollars
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING

Fire Report

Ignition


Heat Source Spark, ember or flame from operating equipment
Item First Ignited Rubbish, trash, or waste
Type of Material Adhesive, resin, tar, glue, asphalt, pitch
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Leak or break

Structure


Number of Residential Units 1

Number of Stories With Damage


Story of Fire Origin 14

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Mobile Property Involved


Mobile Property Type Motor home, camper, bookmobile

Equipment


Equipment Power Solid fuel, other
Equipment Portability Unknown