Report Icon

Incident Report – 06/18/1987
109 Ash, Dodge, NE 68633

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On June 18, 1987, Snyder Volunteer Fire Department responded to a fire incident at 109 Ash, Dodge, NE 68633, a warehouse.

The alarm was received at 7:10 PM and 87 suppression personnel arrived at 7:15 PM. The time to arrive was 5 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address 109 Ash, Dodge, NE 68633
County Dodge County
State NE
City Dodge
Zip Code 68633
Property Use Warehouse
Census Tract 000000
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 5 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received Mutual aid received
Shift 1
Alarms 5
District 008

Personnel


Support Personnel 87
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name Snyder Volunteer Fire Department
Department Type Volunteer
Address 502 W 3RD St
Snyder, NE 68664
Phone (402) 568-2612

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key NE_05008_061887_870001_00
State Nebraska
Fire Department ID 05008
Incident Date 06/18/1987
Incident Number 870001
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Air Conditioning

Legacy Fields


Mutual Aid Yes
Estimated Dollar Loss 400,000
Day of Week Thursday
Time In Service 13:00
Zip Code 68633
Method of Alarm Telephone direct to fire department
Type of Situation Found Structure fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 1
Complex Warehouse, storage complex
Fixed Property Use Freight terminal
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Assembly, Sales Areas not classified above
Level of Fire Origin Grade level to 9 feet above grade
Number of Stories 2
Equipment Involved in Ignition Fixed, stationary local refrigerator unit
Form of Heat of Ignition Heat from properly operating electrical equipment
Type of Material Ignited Man-made fabric, fiber, finished goods
Form of Material Ignited Floor covering, surface
Ignition Factor Mechanical Failure, Malfunction not classified above
Construction Type Unprotected ordinary, not qualifying 5
Extent of Flame Damage Confined to structure of origin
Extent of Smoke Damage Extended beyond structure of origin
Form of Material Generating Most Smoke Supplies, Stock; insufficient information available to classify further
Detector Performance No detectors present
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Rubber
Avenue of Smoke Travel Elevator shaft
Method of Extinguishment Preconnected hose line(s) with water from hydrant, draft, standpipe
Property Damage Classification 250,000-999,999 dollars
Occupancy Type Single or double occupancy
Occupancy Code STORAGE PROPERTY: UNCLASSIFIED

Fire Report

Ignition


Heat Source Radiated, conducted heat from operating equipment
Item First Ignited Floor covering or rug/carpet/mat
Type of Material Fabric, fiber, cotton, blends, rayon, wool
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Mechanical failure, malfunction, other

Number of Stories With Damage


Story of Fire Origin 19

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Mobile Property Involved


Mobile Property Type Passenger road vehicle, other

Equipment


Equipment Power Electrical, other
Equipment Portability Unknown
Sponsored