Summary


On June 22, 2020, City of Lufkin Fire Department responded to a fire incident at 111 N Second St, Lufkin, TX 75901, a mercantile/business.

The alarm was received at 4:45 PM, 10 suppression and 2 other personnel arrived at 4:47 PM, the incident was controlled at 5:00 PM, and the last unit was cleared at 5:36 PM. The time to control the incident was 13 minutes and the total incident time was 51 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Type Street address
Address 111 N Second St, Lufkin, TX 75901
County Angelina County
State TX
City Lufkin
Zip Code 75901
Property Use Mercantile, business, other
Detector Alerted Occupants Unknown
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 13 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 51 minutes

Response


Incident Type Building fires
Department Station 3
Mutual Aid Given/Received None
Resources Include Mutual Aid No

Personnel


Support Personnel 10
EMS Personnel 0
Other Personnel 2

Fire Department


Name City of Lufkin Fire Department
Department Type Career
Address 111 S 3RD St
Lufkin, TX 75901-3043
Phone (936) 633-0376
Website http://cityoflufkin.com/fd/index.htm

Actions Taken


First Action Taken Extinguish

Losses *


Property Loss $4,000
Contents Loss $0
Property Value $6,500
Contents Value $0
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key TX_AC608_06222020_001797_0
State Texas
Fire Department ID AC608
Incident Date 06/22/2020
Incident Number 001797
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Cause


General Cause Electrical
Main Fire Cause Electrical Malfunction
Priority Cause Electrical Dist

Ignition


Area of Origin Roof surface: exterior
Heat Source Arcing
Item First Ignited Electrical wire, cable insulation
Type of Material Type of material first ignited, other
Cause of Ignition Unintentional

Spread


No Flame Spread/Same As First/Unknown Yes
Item Contributing Most To Spread Exterior roof covering or finish
Type Material Contributing Most To Spread Plastic

Structure


Not Residential Yes
Number of Buildings Involved 2
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 2
Building Height: Stories Below Grade 0
Total Square Feet 2400 sqft

Number of Stories With Damage


Story of Fire Origin 2
Number of Stories with Damage: Minor 1
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Equipment


Equipment Power Electrical, other
Equipment Portability Stationary
Sponsored