On June 22, 2020, City of Lufkin Fire Department responded to a fire incident at 111 N Second St, Lufkin, TX 75901, a mercantile/business.
The alarm was received at 4:45 PM, 10 suppression and 2 other personnel arrived at 4:47 PM, the incident was controlled at 5:00 PM, and the last unit was cleared at 5:36 PM. The time to control the incident was 13 minutes and the total incident time was 51 minutes.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Type | Street address |
| Address | 111 N Second St, Lufkin, TX 75901 |
| County | Angelina County |
| State | TX |
| City | Lufkin |
| Zip Code | 75901 |
| Property Use | Mercantile, business, other |
| Detector Alerted Occupants | Unknown |
| Hazardous Material Released | None |
Timeline
Alarm received at
Arrived at
Incident controlled at
Alarm to incident controlled: 13 minutes
Last unit cleared at
Alarm to last unit cleared: 51 minutes
Response
| Incident Type | Building fires |
| Department Station | 3 |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 10 |
| EMS Personnel | 0 |
| Other Personnel | 2 |
Fire Department
| Name | City of Lufkin Fire Department |
| Department Type | Career |
| Address | 111 S 3RD St Lufkin, TX 75901-3043 |
| Phone | (936) 633-0376 |
| Website | http://cityoflufkin.com/fd/index.htm |
Actions Taken
| First Action Taken | Extinguish |
Losses *
| Property Loss | $4,000 |
| Contents Loss | $0 |
| Property Value | $6,500 |
| Contents Value | $0 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | TX_AC608_06222020_001797_0 |
| State | Texas |
| Fire Department ID | AC608 |
| Incident Date | 06/22/2020 |
| Incident Number | 001797 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Cause
| General Cause | Electrical |
| Main Fire Cause | Electrical Malfunction |
| Priority Cause | Electrical Dist |
Ignition
| Area of Origin | Roof surface: exterior |
| Heat Source | Arcing |
| Item First Ignited | Electrical wire, cable insulation |
| Type of Material | Type of material first ignited, other |
| Cause of Ignition | Unintentional |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
| Item Contributing Most To Spread | Exterior roof covering or finish |
| Type Material Contributing Most To Spread | Plastic |
Structure
| Not Residential | Yes |
| Number of Buildings Involved | 2 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 2 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 2400 sqft |
Number of Stories With Damage
| Story of Fire Origin | 2 |
| Number of Stories with Damage: Minor | 1 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Less Than One Acre | Yes |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Stationary |
Sponsored