Report Icon

Incident Report – 02/25/1989
112 E Robinson St, Fredonia, KS 66736

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On February 25, 1989, Fredonia Fire Department responded to a fire incident at 112 E Robinson St, Fredonia, KS 66736, a residential use, residential street/road or residential driveway.

The alarm was received at 7:30 PM and 10 suppression personnel arrived at 7:33 PM. The time to arrive was 3 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address 112 E Robinson St, Fredonia, KS 66736
County Wilson County
State KS
City Fredonia
Zip Code 66736
Mixed Use Residential use
Property Use Residential street, road or residential driveway

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 3 minutes

Response


Incident Type Mobile property (vehicle) fire, other
Mutual Aid Given/Received None
District 004

Personnel


Support Personnel 10
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name Fredonia Fire Department
Department Type Volunteer
Address 100 N 15TH St
Fredonia, KS 66736-1628
Phone (620) 378-2188
Website https://www.fredoniaks.org/index.aspx?nid=100

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key KS_WL201_022589_890010_00
State Kansas
Fire Department ID WL201
Incident Date 02/25/1989
Incident Number 890010
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Electrical Dist

Legacy Fields


Estimated Dollar Loss 2,500
Day of Week Saturday
Time In Service 20:20
Zip Code 66736
Method of Alarm Telephone tie-line to fire department
Type of Situation Found Vehicle fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 0
Complex Dwelling complex (one-and two-family)
Fixed Property Use Paved private street, way
Mobile Property type Automobile
Area of Fire Origin Engine area, running gear, wheel area of transportation equipment
Level of Fire Origin Grade level to 9 feet above grade
Equipment Involved in Ignition Fixed wiring
Form of Heat of Ignition Unspecified short circuit arc
Type of Material Ignited Plastic; insufficient information available to classify further
Form of Material Ignited Electrical wire, cable insulation
Ignition Factor Short circuit, ground fault
Method of Extinguishment Preconnected hose line(s) with water carried in apparatus tanks
Property Damage Classification 1,000-9,999 dollars
Occupancy Type Multiple occupancy
Occupancy Code FIXED USE AMUSEMENT, RECREATION PLACES

Fire Report

Ignition


Heat Source Arcing
Item First Ignited Electrical wire, cable insulation
Type of Material Plastic
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Unspecified short-circuit arc

Number of Stories With Damage


Story of Fire Origin 83

Equipment


Equipment Power Electrical, other
Equipment Portability Unknown

Hazmat Report

Cause of Release


Cause of Release Container or containment failure

Equipment Involved in Release


Legacy Fields

Type of Situation Found Vehicle fire
Complex Dwelling complex (one-and two-family)
Fixed Property Use Paved private street, way
Mobile Property Type Automobile
Area of Fire Origin Engine area, running gear, wheel area of transportation equipment
Equipment Involved in Ignition Fixed wiring
Form of Heat of Ignition Unspecified short circuit arc
Type of Material Ignited Plastic; insufficient information available to classify further
Form of Material Ignited Electrical wire, cable insulation
Ignition Factor Short circuit, ground fault
Dollar Loss $2,500

Mobile Property


Description

Model GTO
Year 69
License Plate BUV157

Legacy Fields

Make PONTIAC
Serial Number 242379R181558
Type of Situation Found Vehicle fire
Complex Dwelling complex (one-and two-family)
Fixed Property Use Paved private street, way
Mobile Property Type Automobile
Area of Fire Origin Engine area, running gear, wheel area of transportation equipment
Equipment Involved in Ignition Fixed wiring
Form of Heat of Ignition Unspecified short circuit arc
Type of Material Ignited Plastic; insufficient information available to classify further
Form of Material Ignited Electrical wire, cable insulation
Ignition Factor Short circuit, ground fault
Time of Arrival 19:30
Dollar Loss $2,500
Sponsored