On June 21, 2018, Hillsboro Department of Public Safety responded to a fire incident at 114 1436, Covington, TX 76636, a 1-or-2 family dwelling.

The alarm was received at 5:39 PM, 1 suppression personnel arrived at 6:25 PM, the incident was controlled at 7:05 PM, and the last unit was cleared at 7:05 PM. The time to arrive was 46 minutes, the time to control the incident was 40 minutes, and the total incident time was 1 hour, 26 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Type Street address
Address 114 1436, Covington, TX 76636
County Hill County
State TX
City COVINGTON
Zip Code 76636
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 46 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 40 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 1 hour, 26 minutes

Response


Incident Type Building fires
Department Station C
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Shift C
Alarms 0
District 3

Personnel


Support Personnel 1
EMS Personnel 0
Other Personnel 0

Fire Department


Name Hillsboro Department of Public Safety
Department Type Career
Address 110 W Franklin St
Hillsboro, TX 76645
Phone (254) 582-2401

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key TX_KP506_06212018_0001052_0
State Texas
Fire Department ID KP506
Incident Date 06/21/2018
Incident Number 0001052
Exposure Number 0
NFIRS Version 5.0

Fire Report

Ignition


Area of Origin Open area - outside; included are farmland, field
Heat Source Heat from other open flame or smoking materials
Item First Ignited Structural component or finish, other
Type of Material LP gas
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Fire spread or control, other

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Total Square Feet 1500 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 1
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Acres Burned 0
Less Than One Acre No

Human Factors Contributing to Ignition


Human Factor Unattended or unsupervised person

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Hardwire with battery
Detector Operation Operated
Detector Effectiveness Alerted Occupants