Incident Report – 08/15/1996 116 West Walnut St, River Falls, WI 54022
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On August 15, 1996, a fire department near River Falls, WI responded to a fire incident at 116 West Walnut St, River Falls, WI 54022, a specialty shop.
The alarm was received at 5:44 PM and 230 suppression personnel arrived at 5:50 PM. The time to arrive was 6 minutes.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Address | 116 West Walnut St, River Falls, WI 54022 |
| County | Pierce County |
| State | WI |
| City | River Falls |
| Zip Code | 54022 |
| Property Use | Specialty shop |
| Census Tract | 960400 |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 6 minutes
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | None |
| Shift | 1 |
| Alarms | 0 |
| District | 01 |
Personnel
| Support Personnel | 230 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | WI_47073_081596_969217_00 |
| State | Wisconsin |
| Fire Department ID | 47073 |
| Incident Date | 08/15/1996 |
| Incident Number | 969217 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Electrical Dist |
Legacy Fields
| Estimated Dollar Loss | 500 |
| Day of Week | Thursday |
| Time In Service | 18:46 |
| Zip Code | 54022 |
| Method of Alarm | Telephone direct to fire department |
| Type of Situation Found | Structure fire |
| Type Action Taken | Extinguishment |
| Number of Aerial Apparatus | 10 |
| Complex | Shopping complex |
| Fixed Property Use | Specialty Shops; insufficient information available to classify further |
| Mobile Property type | Mobile Property Type not applicable |
| Area of Fire Origin | Sales, showroom area |
| Level of Fire Origin | Level of Origin undetermined or not reported |
| Number of Stories | 1 |
| Equipment Involved in Ignition | Fixed wiring |
| Form of Heat of Ignition | Fluorescent light ballast |
| Type of Material Ignited | Wood, Paper; insufficient information available to classify further |
| Form of Material Ignited | Structural member, framing |
| Ignition Factor | Short circuit, ground fault |
| Construction Type | Unprotected ordinary, not qualifying 5 |
| Extent of Flame Damage | Confined to the object of origin |
| Extent of Smoke Damage | Confined to the object of origin |
| Form of Material Generating Most Smoke | Form of Material undetermined or not reported |
| Detector Performance | Performance of Fire Detection Equipment undetermined or not reported |
| Sprinkler Performance | Performance of Automatic Sprinklers undetermined or not reported |
| Type of Material Generating Most Smoke | Wood, Paper; insufficient information available to classify further |
| Avenue of Smoke Travel | No significant avenue of smoke travel |
| Method of Extinguishment | Method of Extinguishment, Control undetermined or not reported |
| Property Damage Classification | 100-999 dollars |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | MERCANTILE PROPERTIES, OFFICES; UNCLASSIFIED |
Fire Report
Ignition
| Heat Source | Radiated, conducted heat from operating equipment |
| Item First Ignited | Structural member or framing |
| Type of Material | Wood or paper, processed, other |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Fluorescent light ballast |
Number of Stories With Damage
| Story of Fire Origin | 15 |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Mobile Property Involved
| Mobile Property Type | Trailer - travel, designed to be towed |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Unknown |