Report Icon

Incident Report – 12/13/1988
127 S Circle Dr, Morgan, UT 84050

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On December 13, 1988, Morgan County Fire Department responded to a fire incident at 127 S Circle Dr, Morgan, UT 84050, a residential use, 1-or-2 family dwelling.

The alarm was received at 9:53 PM and 13 suppression personnel arrived at 9:57 PM. The time to arrive was 4 minutes.

The following action was taken during the incident: standby.

Sponsored

Location


Address 127 S Circle Dr, Morgan, UT 84050
County Morgan County
State UT
City Morgan
Zip Code 84050
Mixed Use Residential use
Property Use 1 or 2 family dwelling
Census Tract 000000
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 4 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received None
Shift 0
Alarms 1
District 000

Personnel


Support Personnel 13
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name Morgan County Fire Department
Department Type Mostly volunteer
Address 41 N State St
Morgan, UT 84050
Phone (801) 845-4048

Actions Taken


First Action Taken Standby

Metadata


Incident Key UT_29002_121388_888034_00
State Utah
Fire Department ID 29002
Incident Date 12/13/1988
Incident Number 888034
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Unclassified equip. w/ other or unknown fuel source

Legacy Fields


Estimated Dollar Loss 0
Day of Week Tuesday
Time In Service 22:27
Zip Code 84050
Method of Alarm Telephone tie-line to fire department
Type of Situation Found Structure fire
Type Action Taken Standby
Number of Aerial Apparatus 0
Complex Dwelling complex (one-and two-family)
Fixed Property Use One-family dwelling: year-round use
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Chimney
Level of Fire Origin Grade level to 9 feet above grade
Number of Stories 1
Equipment Involved in Ignition No equipment involved
Form of Heat of Ignition Heat from solid fueled equipment
Type of Material Ignited Adhesive, resin, tar
Form of Material Ignited Rubbish, trash, waste
Ignition Factor Operational Deficiency not classified above
Construction Type Protected ordinary
Extent of Flame Damage Extent of Flame Damage undetermined or not reported
Extent of Smoke Damage No damage of this type
Form of Material Generating Most Smoke Type of Material not applicable
Detector Performance No detectors present
Sprinkler Performance No equipment present in room or space of fire origin
Avenue of Smoke Travel No significant avenue of smoke travel
Method of Extinguishment Self-extinguished
Property Damage Classification Undertermined
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING

Fire Report

Ignition


Heat Source Radiated, conducted heat from operating equipment
Item First Ignited Rubbish, trash, or waste
Type of Material Adhesive, resin, tar, glue, asphalt, pitch
Cause of Ignition Unintentional
Factor Contributing To Ignition Operational deficiency, other

Structure


Number of Residential Units 1

Number of Stories With Damage


Story of Fire Origin 57

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Mobile Property Involved


Mobile Property Type Military non fixed wing aircraft

Equipment


Equipment Power Solid fuel, other
Equipment Portability Unknown