Incident Report – 03/20/2019 131 Morgan St, Cuthbert, GA 39840
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On March 20, 2019, Cuthbert Fire Department responded to a fire incident at 131 Morgan St, Cuthbert, GA 39840, a 1-or-2 family dwelling.
The alarm was received at 10:47 AM, 8 suppression personnel arrived at 10:49 AM, the incident was controlled at 11:48 AM, and the last unit was cleared at 12:40 PM. The time to control the incident was 59 minutes and the total incident time was 1 hour, 53 minutes.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Type | Street address |
| Address | 131 Morgan St, Cuthbert, GA 39840 |
| County | Randolph County |
| State | GA |
| City | Cuthbert |
| Zip Code | 39840 |
| Property Use | 1 or 2 family dwelling |
| Detector Alerted Occupants | Detector did not alert occupants |
Timeline
Alarm received at
Arrived at
Incident controlled at
Alarm to incident controlled: 59 minutes
Last unit cleared at
Alarm to last unit cleared: 1 hour, 53 minutes
Response
| Incident Type | Building fires |
| Department Station | 033 |
| Mutual Aid Given/Received | Other aid given (the aid-giving department is responding to an area that has no fire department of its own) |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 8 |
| EMS Personnel | 0 |
| Other Personnel | 0 |
Fire Department
| Name | Cuthbert Fire Department |
| Department Type | Career |
| Address | 668 Blakely St Cuthbert, GA 31740 |
| Phone | (229) 732-6454 |
Actions Taken
| First Action Taken | Extinguish |
Losses *
| Property Loss | $5,000 |
| Contents Loss | $5,000 |
| Property Value | $5,000 |
| Contents Value | $5,000 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | GA_12001_03202019_19069_0 |
| State | Georgia |
| Fire Department ID | 12001 |
| Incident Date | 03/20/2019 |
| Incident Number | 19069 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Cause
| General Cause | Equipment |
| Main Fire Cause | Equipment Misoperation, Failure |
| Priority Cause | Equipment Operation Deficiency |
Ignition
| Area of Origin | Cooking area, kitchen |
| Heat Source | Heat from direct flame, convection currents |
| Item First Ignited | Cabinetry (including built-in) |
| Type of Material | Cooking oil, transformer or lubricating oil |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Equipment unattended |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
Structure
| Not Residential | No |
| Number of Residential Units | 2 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 2 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 120 sqft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
Acres
| Less Than One Acre | No |
Human Factors Contributing to Ignition
| Human Factor | Possibly impaired by alcohol or drugs |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | Detectors Present |
| Detector Type | Smoke |
| Detector Power | Battery Only |
| Detector Operation | Operated |
| Detector Effectiveness | No occupants |