Report Icon

Incident Report – 12/14/2012
133 Kelso St, Eagle Point, OR 97524

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On December 14, 2012, a fire department near Eagle Point, OR responded to a fire incident at 133 Kelso St, Eagle Point, OR 97524, a 1-or-2 family dwelling.

The alarm was received at 7:00 AM, 4 suppression personnel arrived at 7:04 AM, the incident was controlled at 7:10 AM, and the last unit was cleared at 7:26 AM. The time to arrive was 4 minutes, the time to control the incident was 6 minutes, and the total incident time was 26 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Type Street address
Address 133 Kelso St, Eagle Point, OR 97524
County Jackson County
State OR
City Eagle Point
Zip Code 97524
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Unknown
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 4 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 6 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 26 minutes

Response


Incident Type Chimney or flue fire, confined to chimney or flue
Department Station EP
Mutual Aid Given/Received None
Resources Include Mutual Aid No

Personnel


Support Personnel 4
EMS Personnel 0
Other Personnel 0

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key OR_0173_12142012_0005472_0
State Oregon
Fire Department ID 0173
Incident Date 12/14/2012
Incident Number 0005472
Exposure Number 0
NFIRS Version 5.0

Fire Report

Cause


General Cause Equipment
Main Fire Cause Heating
Priority Cause Heating

Ignition


Area of Origin Conduit, pipe, utility, or ventilation shaft
Heat Source Heat from direct flame, convection currents
Item First Ignited Film, residue, including paint & resin
Confined To Origin Fire Spread was Confined to Object of Origin
Type of Material Adhesive, resin, tar, glue, asphalt, pitch
Cause of Ignition Unintentional
Factor Contributing To Ignition Failure to clean

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Total Square Feet 1300 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Acres Burned 0
Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Battery Only
Detector Operation Operated
Detector Effectiveness Undetermined

Equipment


Equipment Power Wood, paper
Equipment Portability Stationary
Sponsored