On April 9, 2020, Cuba Fire Protection District responded to a fire incident at 13839 E Asbell Rd, Fiatt, IL 61433, a storage facility.
The alarm was received at 11:28 AM, 12 suppression and 2 other personnel arrived at 11:43 AM, the incident was controlled at 11:55 AM, and the last unit was cleared at 12:07 PM. The time to arrive was 15 minutes, the time to control the incident was 12 minutes, and the total incident time was 39 minutes.
The following actions were taken during the incident: extinguish, provide manpower, and provide apparatus.
Sponsored
Location
| Type | Street address |
| Address | 13839 E Asbell Rd, Fiatt, IL 61433 |
| County | Fulton County |
| State | IL |
| City | Fiatt |
| Zip Code | 61433 |
| Property Use | Storage, other |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 15 minutes
Incident controlled at
Alarm to incident controlled: 12 minutes
Last unit cleared at
Alarm to last unit cleared: 39 minutes
Response
| Incident Type | Building fires |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 12 |
| EMS Personnel | 0 |
| Other Personnel | 2 |
Fire Department
| Name | Cuba Fire Protection District |
| Department Type | Volunteer |
| Address | 411 E Jefferson St Cuba, IL 61427 |
| Phone | (309) 785-5219 |
Actions Taken
| First Action Taken | Extinguish |
| Second Action Taken | Provide manpower |
| Third Action Taken | Provide apparatus |
Metadata
| Incident Key | IL_FD183_04092020_0020020_0 |
| State | Illinois |
| Fire Department ID | FD183 |
| Incident Date | 04/09/2020 |
| Incident Number | 0020020 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
Fire Report
Cause
| General Cause | Electrical |
| Main Fire Cause | Electrical Malfunction |
| Priority Cause | Unclassified elec malfunction |
Ignition
| Area of Origin | Vehicle storage area; garage, carport |
| Heat Source | Arcing |
| Item First Ignited | Electrical wire, cable insulation |
| Type of Material | Plastic |
| Cause of Ignition | Cause undetermined after investigation |
| Factor Contributing To Ignition | Undetermined |
On-Site Materials
| On-Site Material | Tools (power & hand tools) |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
| Item Contributing Most To Spread | Undetermined |
Structure
| Not Residential | Yes |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 200 sqft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 1 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Less Than One Acre | No |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Sponsored