Incident Report – 02/28/2016 14097 River St, Blakely, GA 39823
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On February 28, 2016, City of Blakely Fire Department responded to a fire incident at 14097 River St, Blakely, GA 39823, a residential use, 1-or-2 family dwelling.
The alarm was received at 10:01 AM, 9 suppression personnel arrived at 10:05 AM, the incident was controlled at 10:15 AM, and the last unit was cleared at 12:12 PM. The time to arrive was 4 minutes, the time to control the incident was 10 minutes, and the total incident time was 11 minutes.
The following actions were taken during the incident: extinguish and establish safe area.
Sponsored
Location
| Type | Street address |
| Address | 14097 River St, Blakely, GA 39823 |
| County | Early County |
| State | GA |
| City | Blakely |
| Zip Code | 39823 |
| Mixed Use | Residential use |
| Property Use | 1 or 2 family dwelling |
| Census Tract | 009903 |
| Detector Alerted Occupants | Detector alerted occupants |
| Hazardous Material Released | None |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 4 minutes
Incident controlled at
Alarm to incident controlled: 10 minutes
Last unit cleared at
Alarm to last unit cleared: 11 minutes
Response
| Incident Type | Building fires |
| Department Station | 1 |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
| Shift | 2 |
| Alarms | 1 |
| District | 50 |
Personnel
| Support Personnel | 9 |
| EMS Personnel | 0 |
| Other Personnel | 0 |
Fire Department
| Name | City of Blakely Fire Department |
| Department Type | Mostly career |
| Address | 12667 Magnolia St Blakely, GA 39823 |
| Phone | (229) 723-5150 |
Actions Taken
| First Action Taken | Extinguish |
| Second Action Taken | Establish safe area |
Losses *
| Property Loss | $12,000 |
| Contents Loss | $5,000 |
| Property Value | $12,000 |
| Contents Value | $5,000 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | GA_04902_02282016_1602039_0 |
| State | Georgia |
| Fire Department ID | 04902 |
| Incident Date | 02/28/2016 |
| Incident Number | 1602039 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Ignition
| Area of Origin | Bedroom - < 5 persons; included are jail or prison |
| Heat Source | Arcing |
| Item First Ignited | Interior wall covering excluding drapes, etc |
| Type of Material | Fiberboard, particleboard, and hardboard |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Electrical failure, malfunction, other |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
| Item Contributing Most To Spread | Structural component or finish, other |
| Type Material Contributing Most To Spread | Plywood |
Structure
| Not Residential | No |
| Number of Residential Units | 1 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 0 |
| Building Length | 60 ft |
| Building Width | 24 ft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 0 |
| Number of Stories with Damage: Significant | 1 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Acres Burned | 0 |
| Less Than One Acre | No |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | Detectors Present |
| Detector Type | Smoke |
| Detector Power | Plug in with battery |
| Detector Operation | Operated |
| Detector Effectiveness | Alerted Occupants |
Sponsored