Summary
On December 20, 2020, Grapevine Fire Department responded to a fire incident at 1411 Rio Bend Ct, Grapevine, TX 76051, a 1-or-2 family dwelling.
The alarm was received at 7:04 PM, 17 suppression, 4 EMS, and 2 other personnel arrived at 7:07 PM, the incident was controlled at 7:18 PM, and the last unit was cleared at 7:54 PM. The time to arrive was 3 minutes, the time to control the incident was 11 minutes, and the total incident time was 50 minutes.
The following actions were taken during the incident: extinguish and salvage and overhaul.
Sponsored
Location
| Type | Street address |
| Address | 1411 Rio Bend Ct, Grapevine, TX 76051 |
| County | Tarrant County |
| State | TX |
| City | Grapevine |
| Zip Code | 76051 |
| Property Use | 1 or 2 family dwelling |
| Detector Alerted Occupants | Detector alerted occupants |
| Hazardous Material Released | None |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 3 minutes
Incident controlled at
Alarm to incident controlled: 11 minutes
Last unit cleared at
Alarm to last unit cleared: 50 minutes
Response
| Incident Type | Building fires |
| Department Station | 2 |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 17 |
| EMS Personnel | 4 |
| Other Personnel | 2 |
Fire Department
| Name | Grapevine Fire Department |
| Department Type | Career |
| Address | 1007 Ira E Woods Ave Grapevine, TX 76051-4018 |
| Phone | (817) 410-4400 |
| Website | http://grapevinetexas.gov/1233/Fire |
Actions Taken
| First Action Taken | Extinguish |
| Second Action Taken | Salvage & overhaul |
Metadata
| Incident Key | TX_WB616_12202020_005442_0 |
| State | Texas |
| Fire Department ID | WB616 |
| Incident Date | 12/20/2020 |
| Incident Number | 005442 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
Fire Report
Cause
| General Cause | Equipment |
| Main Fire Cause | Heating |
| Priority Cause | Heating |
Ignition
| Area of Origin | Attic: vacant, crawl space above top story, cupola |
| Heat Source | Radiated, conducted heat from operating equipment |
| Item First Ignited | Structural member or framing |
| Confined To Origin | Fire Spread was Confined to Object of Origin |
| Type of Material | Sawn wood, including all finished lumber |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Undetermined |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
Structure
| Not Residential | No |
| Number of Residential Units | 2 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 2 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 2000 sqft |
Number of Stories With Damage
| Story of Fire Origin | 2 |
| Number of Stories with Damage: Minor | 1 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Less Than One Acre | Yes |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | Detectors Present |
| Detector Type | Smoke |
| Detector Power | Battery Only |
| Detector Operation | Operated |
| Detector Effectiveness | Alerted Occupants |
Equipment
| Equipment Power | Wood, paper |
| Equipment Portability | Stationary |