Report Icon

Incident Report – 11/29/2022
1420 Ary Ln, Dixon, CA 95620

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On November 29, 2022, Dixon Fire Department responded to a fire incident at 1420 Ary Ln, Dixon, CA 95620, a restaurant/cafeteria.

The alarm was received at 7:45 AM, 8 suppression and 1 other personnel arrived at 7:51 AM, and the last unit was cleared at 8:19 AM. The time to arrive was 6 minutes and the total incident time was 34 minutes.

The following action was taken during the incident: investigate.

Sponsored

Location


Type Street address
Address 1420 Ary Ln, Dixon, CA 95620
County Solano County
State CA
City Dixon
Zip Code 95620
Property Use Restaurant or cafeteria
Detector Alerted Occupants Unknown
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 6 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 34 minutes

Response


Incident Type Outside equipment fire
Department Station 81
Mutual Aid Given/Received None
Resources Include Mutual Aid No

Personnel


Support Personnel 8
EMS Personnel 0
Other Personnel 1

Fire Department


Name Dixon Fire Department
Department Type Mostly career
Address 205 Ford Way
DIXON, CA 95620-3162
Phone (707) 678-7060
Website https://www.cityofdixon.us/departments/Fire

Actions Taken


First Action Taken Investigate

Losses *


Property Loss $1,000
Contents Loss $0
Property Value $1,000
Contents Value $0
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key CA_48015_11292022_0002783_0
State California
Fire Department ID 48015
Incident Date 11/29/2022
Incident Number 0002783
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Ignition


Area of Origin Duct: hvac, cable, exhaust, heating, or AC
Heat Source Radiated, conducted heat from operating equipment
Item First Ignited Conveyor belt, drive belt, V-belt
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Mechanical failure, malfunction, other

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential Yes
Number of Buildings Involved 0

Acres


Less Than One Acre Yes

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary
Sponsored