On January 21, 2018, Wethersfield Volunteer Fire Department responded to a fire incident at 151 Eastern Dr, Wethersfield, CT 06109, a 1-or-2 family dwelling.

The alarm was received at 5:57 PM, 21 suppression personnel arrived at 6:02 PM, and the last unit was cleared at 6:47 PM. The time to arrive was 5 minutes and the total incident time was 50 minutes.

The following actions were taken during the incident: extinguish and ventilate.

Sponsored

Location


Type Street address
Address 151 Eastern Dr, Wethersfield, CT 06109
County Hartford County
State CT
City WETHERSFIELD
Zip Code 06109
Property Use 1 or 2 family dwelling
Census Tract 4924
Detector Alerted Occupants Detector alerted occupants

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 5 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 50 minutes

Response


Incident Type Building fires
Department Station FMO
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Shift L
Alarms 0
District D3

Personnel


Support Personnel 21
EMS Personnel 0
Other Personnel 0

Fire Department


Name Wethersfield Volunteer Fire Department
Department Type Volunteer
Address 505 Silas Deane Hwy
Wethersfield, CT 06109-2216
Phone (860) 721-2830
Website https://www.wvfd.org

Actions Taken


First Action Taken Extinguish
Second Action Taken Ventilate

Losses *


Property Loss $2,000
Contents Loss $5,000
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key CT_02270_01212018_0001039_0
State Connecticut
Fire Department ID 02270
Incident Date 01/21/2018
Incident Number 0001039
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Ignition


Area of Origin Substructure area or space, crawl space
Heat Source Arcing
Item First Ignited Electrical wire, cable insulation
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Electrical failure, malfunction, other

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 0
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 2
Building Height: Stories Below Grade 0
Total Square Feet 2700 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Acres Burned 0
Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Operation Operated
Detector Effectiveness Alerted Occupants

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Portable