On June 10, 2006, Middletown Fire Department responded to a fire incident at 16 Putter Pl, Middletown, CT 06457, a 1-or-2 family dwelling.

The following actions were taken during the incident: salvage and overhaul and ventilate.

Sponsored

Location


Type Street address
Address 16 Putter Pl, Middletown, CT 06457
County Middlesex County
State CT
City Middletown
Zip Code 06457
Property Use 1 or 2 family dwelling
Census Tract 005422

Response


Incident Type Building fires
Department Station ALL
Mutual Aid Given/Received Automatic aid received
Resources Include Mutual Aid No
Shift 4
Alarms 1
District M01

Fire Department


Name Middletown Fire Department
Department Type Career
Address 533 Main St
Middletown, CT 06457-2809
Phone (860) 638-3200

Actions Taken


First Action Taken Salvage & overhaul
Second Action Taken Ventilate

Metadata


Incident Key CT_07120_6102006_0001694_0
State Connecticut
Fire Department ID 07120
Incident Date 06/10/2006
Incident Number 0001694
Exposure Number 0
NFIRS Version 5.0

Fire Report

Ignition


Area of Origin Duct: hvac, cable, exhaust, heating, or AC
Heat Source Heat from powered equipment, other
Item First Ignited Dust, fiber, lint, including sawdust and excelsior
Confined To Origin Fire Spread was Confined to Object of Origin
Cause of Ignition Cause under investigation
Factor Contributing To Ignition Undetermined

On-Site Materials


On-Site Material Appliances

Spread


No Flame Spread/Same As First/Unknown No

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Structure type, other
Structure Status In normal use
Building Height: Stories Above Grade 2
Building Height: Stories Below Grade 1
Number of Sprinklers Operating 0

Number of Stories With Damage


Story of Fire Origin 0
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Acres Burned 0
Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Hardwire with battery
Detector Operation Operated
Detector Effectiveness Alerted Occupants

Mobile Property Involved


Mobile Property Year 0

Equipment


Equipment Brand Whirlpool
Equipment Model LER4634JQ0
Equipment Serial Number ML3261970
Equipment Year 0
Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary