On March 28, 2022, Mobile Fire-Rescue Department responded to a fire incident at 1605 Jasper Rd, Mobile, AL 36618, a 1-or-2 family dwelling.

The alarm was received at 6:59 AM, 36 suppression and 4 EMS personnel arrived at 7:05 AM, and the last unit was cleared at 7:41 AM. The time to arrive was 6 minutes and the total incident time was 42 minutes.

The following action was taken during the incident: extinguish.

As a result of the incident, there was 1 fire service injury.

Sponsored

Location


Type Street address
Address 1605 Jasper Rd, Mobile, AL 36618
County Mobile County
State AL
City Mobile
Zip Code 36618
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Detector alerted occupants

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 6 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 42 minutes

Response


Incident Type Building fires
Department Station Sta
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Shift C
District 101

Personnel


Support Personnel 36
EMS Personnel 4
Other Personnel 0

Fire Department


Name Mobile Fire-Rescue Department
Department Type Career
Address 701 Saint Francis St
Mobile, AL 36602-1818
Phone (251) 208-7351
Website https://www.cityofmobile.org/fire/

Actions Taken


First Action Taken Extinguish

Injuries/Deaths


Fire Service Injuries 1
Fire Service Deaths 0

Losses *


Property Loss $500
Contents Loss $0
Property Value $100,000
Contents Value $30,000
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key AL_00201_03282022_2209182_0
State Alabama
Fire Department ID 00201
Incident Date 03/28/2022
Incident Number 2209182
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Cause


General Cause Equipment
Main Fire Cause Appliances
Priority Cause Air Conditioning

Ignition


Area of Origin Duct: hvac, cable, exhaust, heating, or AC
Heat Source Heat from powered equipment, other
Item First Ignited Item First Ignited, Other
Type of Material Plastic
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Mechanical failure, malfunction, other

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Building Length 50 ft
Building Width 30 ft

Number of Stories With Damage


Story of Fire Origin 1

Acres


Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Hardwire Only
Detector Operation Operated
Detector Effectiveness Alerted Occupants

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary

Firefighter Casualty Report

Injured Person


Gender Male
Age 37

Injury Date and Time


Injury Date and Time 03/28/2022 7:06 AM

Responses


Prior Responses During Past 24 Hours 0

Physical Condition


Physical Condition Rested

Severity


Severity Lost time injury, moderate severity

Taken To


Taken To Taken to, other

Activity At Time Of Injury


Activity At Time of Injury Laying hose

Injury


Primary Apparent Symptom Pain only
Primary Area of Body Injured Ankle
Factor Contributing to Injury Slippery or uneven surfaces, other
Where Injury Occurred At scene, outside
Injury Relation to Structure Outside of structure
Specific Location Outside at grade
Protective Equipment Contributed to Injury No