Incident Report – 02/09/2019 1605 N Tasker Dr, Hobbs, NM 88240
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On February 9, 2019, City of Hobbs Fire Department responded to a fire incident at 1605 N Tasker Dr, Hobbs, NM 88240, a residential property.
The alarm was received at 9:37 AM, 8 suppression, 3 EMS, and 2 other personnel arrived at 9:42 AM, the incident was controlled at 11:34 AM, and the last unit was cleared at 11:37 AM. The time to arrive was 5 minutes and the time to control the incident was 1 hour, 52 minutes.
The following actions were taken during the incident: provide manpower, provide apparatus, and provide equipment.
Sponsored
Location
| Type | Street address |
| Address | 1605 N Tasker Dr, Hobbs, NM 88240 |
| County | Lea County |
| State | NM |
| City | Hobbs |
| Zip Code | 88240 |
| Property Use | Residential, other |
| Detector Alerted Occupants | Unknown |
| Hazardous Material Released | None |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 5 minutes
Incident controlled at
Alarm to incident controlled: 1 hour, 52 minutes
Last unit cleared at
Response
| Incident Type | Building fires |
| Department Station | ST3 |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 8 |
| EMS Personnel | 3 |
| Other Personnel | 2 |
Fire Department
| Name | City of Hobbs Fire Department |
| Department Type | Career |
| Address | 301 E White St Hobbs, NM 88240 |
| Phone | (505) 397-9308 |
| Website | www.hobbsfire.com |
Actions Taken
| First Action Taken | Provide manpower |
| Second Action Taken | Provide apparatus |
| Third Action Taken | Provide equipment |
Metadata
| Incident Key | NM_25013_02092019_190168_0 |
| State | New Mexico |
| Fire Department ID | 25013 |
| Incident Date | 02/09/2019 |
| Incident Number | 190168 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
Fire Report
Cause
| General Cause | Electrical |
| Main Fire Cause | Electrical Malfunction |
| Priority Cause | Electrical Dist |
Ignition
| Area of Origin | Common room, den, family room, living room, lounge |
| Heat Source | Heat from powered equipment, other |
| Item First Ignited | Electrical wire, cable insulation |
| Type of Material | Fabric, fiber, cotton, blends, rayon, wool |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Electrical failure, malfunction, other |
| Factor Contributing To Ignition | Misuse of material or product, other |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
Structure
| Not Residential | No |
| Number of Residential Units | 1 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 1800 sqft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 1 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Less Than One Acre | Yes |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | Undetermined |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Portable |
Sponsored