Incident Report – 12/18/2005 1708 130th St, Wellman, IA 52356
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On December 18, 2005, Wellman Volunteer Fire Department responded to a fire incident at 1708 130th St, Wellman, IA 52356, a livestock production property.
The alarm was received at 11:04 AM, 15 suppression personnel arrived at 11:12 AM, the incident was controlled at 11:15 AM, and the last unit was cleared at 11:28 AM. The time to arrive was 8 minutes, the time to control the incident was 3 minutes, and the total incident time was 24 minutes.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Type | Street address |
| Address | 1708 130th St, Wellman, IA 52356 |
| County | Washington County |
| State | IA |
| City | WELLMAN |
| Zip Code | 52356 |
| Property Use | Livestock production |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 8 minutes
Incident controlled at
Alarm to incident controlled: 3 minutes
Last unit cleared at
Alarm to last unit cleared: 24 minutes
Response
| Incident Type | Building fires |
| Department Station | 1 |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
| Alarms | 0 |
Personnel
| Support Personnel | 15 |
| EMS Personnel | 0 |
| Other Personnel | 0 |
Fire Department
| Name | Wellman Volunteer Fire Department |
| Department Type | Volunteer |
| Address | 95 3RD St Wellman, IA 52356 |
| Phone | (319) 646-2422 |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | IA_92007_12182005_0000045_0 |
| State | Iowa |
| Fire Department ID | 92007 |
| Incident Date | 12/18/2005 |
| Incident Number | 0000045 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
Fire Report
Ignition
| Area of Origin | Egress/exit, other |
| Heat Source | Heat from powered equipment, other |
| Item First Ignited | Interior wall covering excluding drapes, etc |
| Type of Material | Plywood |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Equipment not being operated properly |
On-Site Materials
| On-Site Material | Livestock |
Spread
| No Flame Spread/Same As First/Unknown | No |
Structure
| Not Residential | Yes |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 5000 sqft |
| Number of Sprinklers Operating | 0 |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 0 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Acres Burned | 0 |
| Less Than One Acre | Yes |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Mobile Property Involved
| Mobile Property Year | 0 |
Equipment
| Equipment Year | 0 |