Report Icon

Incident Report – 05/09/2016
1736 Bridle Ln, Macon, GA 31220

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On May 9, 2016, Macon-Bibb County Fire Department responded to a fire incident at 1736 Bridle Ln, Macon, GA 31220, a residential use, 1-or-2 family dwelling.

The alarm was received at 4:45 PM, 11 suppression and 2 EMS personnel arrived at 4:51 PM, and the last unit was cleared at 5:22 PM. The time to arrive was 6 minutes and the total incident time was 37 minutes.

The following actions were taken during the incident: establish safe area and investigate.

Sponsored

Location


Type Street address
Address 1736 Bridle Ln, Macon, GA 31220
County Bibb County
State GA
City MACON
Zip Code 31220
Mixed Use Residential use
Property Use 1 or 2 family dwelling

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 6 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 37 minutes

Response


Incident Type Building fires
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Shift S
Alarms 1
District 08

Personnel


Support Personnel 11
EMS Personnel 2
Other Personnel 0

Fire Department


Name Macon-Bibb County Fire Department
Department Type Career
Address 1191 First St
PO Box 247
Macon, GA 31201
Phone (478) 751-2700

Actions Taken


First Action Taken Establish safe area
Second Action Taken Investigate

Metadata


Incident Key GA_01101_05092016_0008582_0
State Georgia
Fire Department ID 01101
Incident Date 05/09/2016
Incident Number 0008582
Exposure Number 0
NFIRS Version 5.0

Fire Report

Ignition


Area of Origin Cooking area, kitchen
Heat Source Arcing
Item First Ignited Electrical wire, cable insulation
Confined To Origin Fire Spread was Confined to Object of Origin
Type of Material Material compounded with oil, other
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Arc, spark from operating equipment

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 2
Building Height: Stories Below Grade 0
Total Square Feet 1400 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Suppression Factors


Suppression Factor Secured area
Suppression Factor Insulation combustible
Suppression Factor Flammable/combustible liquid hazard

Detector


Detector Presence None Present
Sponsored