Summary
On July 26, 2012, Natchitoches Parish Fire District #5 responded to a fire incident at 186 Johnson Loop, Natchez, LA 71456, a 1-or-2 family dwelling.
The alarm was received at 2:52 PM, 3 suppression personnel arrived at 3:04 PM, and the last unit was cleared at 3:18 PM. The time to arrive was 12 minutes and the total incident time was 26 minutes.
The following action was taken during the incident: fire/other.
Sponsored
Location
| Type | Street address |
| Address | 186 Johnson Loop, Natchez, LA 71456 |
| County | Natchitoches Parish |
| State | LA |
| City | Natchez |
| Zip Code | 71456 |
| Property Use | 1 or 2 family dwelling |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 12 minutes
Last unit cleared at
Alarm to last unit cleared: 26 minutes
Response
| Incident Type | Building fires |
| Department Station | FD5 |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
| Shift | D |
| Alarms | 0 |
| District | FD5 |
Personnel
| Support Personnel | 3 |
| EMS Personnel | 0 |
| Other Personnel | 0 |
Fire Department
| Name | Natchitoches Parish Fire District #5 |
| Department Type | Volunteer |
| Address | 181 Main St PO Box 340 Natchez, LA 71456 |
| Phone | (318) 352-1046 |
Actions Taken
| First Action Taken | Fire, other |
Losses *
| Property Loss | $150 |
| Contents Loss | $0 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | LA_35047_07262012_0000017_0 |
| State | Louisiana |
| Fire Department ID | 35047 |
| Incident Date | 07/26/2012 |
| Incident Number | 0000017 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Ignition
| Area of Origin | Wall surface: exterior |
| Heat Source | Arcing |
| Item First Ignited | Exterior wall covering or finish |
| Confined To Origin | Fire Spread was Confined to Object of Origin |
| Type of Material | Fiberboard, particleboard, and hardboard |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Unspecified short-circuit arc |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
Structure
| Not Residential | No |
| Number of Residential Units | 1 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 1200 sqft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 1 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Acres Burned | 0 |
| Less Than One Acre | No |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | Undetermined |
Equipment
| Equipment Power | Electrical line voltage (>= 50 volts) |
| Equipment Portability | Stationary |