On March 26, 2012, Ammon Fire Department responded to a fire incident at 1975 Bittern Dr, Ammon, ID 83406, a residential use, 1-or-2 family dwelling.

The alarm was received at 8:59 PM, 5 suppression and 1 other personnel arrived at 9:10 PM, the incident was controlled at 9:15 PM, and the last unit was cleared at 9:43 PM. The time to arrive was 11 minutes, the time to control the incident was 5 minutes, and the total incident time was 44 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Type Street address
Address 1975 Bittern Dr, Ammon, ID 83406
County Bonneville County
State ID
City Ammon
Zip Code 83406
Mixed Use Residential use
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Detector did not alert occupants
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 11 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 5 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 44 minutes

Response


Incident Type Outside equipment fire
Department Station 1
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Alarms 0

Personnel


Support Personnel 5
EMS Personnel 0
Other Personnel 1

Fire Department


Name Ammon Fire Department
Department Type Mostly volunteer
Address 2135 S Ammon Rd
Ammon, ID 83406-6855
Phone (208) 612-4000
Website https://www.ci.ammon.id.us/fire.cfm

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key ID_19315_03262012_0000023_0
State Idaho
Fire Department ID 19315
Incident Date 03/26/2012
Incident Number 0000023
Exposure Number 0
NFIRS Version 5.0

Fire Report

Ignition


Area of Origin Conduit, pipe, utility, or ventilation shaft
Heat Source Arcing
Item First Ignited Fence, pole
Type of Material Round timber, including round posts, poles
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Electrical failure, malfunction, other

On-Site Materials


On-Site Material Trees, plants, flowers

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 0

Acres


Acres Burned 0
Less Than One Acre No

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary
Sponsored