Report Icon

Incident Report – 12/20/1989
1st S & Main, Koosharem, UT 84744

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On December 20, 1989, Koosharem Fire Department responded to a fire incident at 1st S & Main, Koosharem, UT 84744, a residential use, 1-or-2 family dwelling.

The alarm was received at 3:06 AM and 6 suppression personnel arrived at 3:12 AM. The time to arrive was 6 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address 1st S & Main, Koosharem, UT 84744
County Sevier County
State UT
City Koosharem
Zip Code 84744
Mixed Use Residential use
Property Use 1 or 2 family dwelling
Census Tract 000000
Detector Alerted Occupants Detector did not alert occupants

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 6 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received Mutual aid received
Shift 0
Alarms 0
District 000

Personnel


Support Personnel 6
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name Koosharem Fire Department
Department Type Volunteer
Address 55 N Main
Koosharem, UT 84744
Phone (435) 638-7598

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key UT_41006_122089_890006_00
State Utah
Fire Department ID 41006
Incident Date 12/20/1989
Incident Number 890006
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Heating

Legacy Fields


Mutual Aid Yes
Estimated Dollar Loss 30,000
Day of Week Wednesday
Zip Code 84744
Method of Alarm Radio
Type of Situation Found Structure fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 0
Complex Dwelling complex (one-and two-family)
Fixed Property Use One-family dwelling: year-round use
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Structural Areas not classified above
Level of Fire Origin Below ground level or water level
Number of Stories 1
Equipment Involved in Ignition Fixed, stationary local heating unit
Form of Heat of Ignition Heat from Hot Object; insufficient information available to classify further
Type of Material Ignited Sawn wood
Form of Material Ignited Structural member, framing
Ignition Factor Installed too close to combustibles
Construction Type Protected Wood Frame
Extent of Flame Damage Confined to structure of origin
Extent of Smoke Damage Confined to structure or origin
Form of Material Generating Most Smoke Structural member, framing
Detector Performance Detector(s) not in the room or space of fire origin, and they operated
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Sawn wood
Avenue of Smoke Travel Air handling duct
Method of Extinguishment Hand-laid hose line(s) with water from standpipe, hydrant, draft
Property Damage Classification 25,000-49,999 dollars
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING

Fire Report

Ignition


Heat Source Hot or smoldering object, other
Item First Ignited Structural member or framing
Type of Material Sawn wood, including all finished lumber
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Installation deficiency

Structure


Number of Residential Units 1

Number of Stories With Damage


Story of Fire Origin 79

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Operation Operated
Detector Effectiveness Undetermined
Sponsored