Report Icon

Incident Report – 07/06/2017
2 Edgewood, Avon, CT 06001

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On July 6, 2017, Avon Volunteer Fire Department, Inc. responded to a fire incident at 2 Edgewood, Avon, CT 06001, a non-mixed use, 1-or-2 family dwelling.

The alarm was received at 1:54 PM, 2 suppression and 36 other personnel arrived at 2:05 PM, and the last unit was cleared at 3:47 PM. The time to arrive was 11 minutes and the total incident time was 1 hour, 53 minutes.

The following actions were taken during the incident: extinguish and shut down system.

Sponsored

Location


Type Street address
Address 2 Edgewood, Avon, CT 06001
County Hartford County
State CT
City AVON
Zip Code 06001
Mixed Use Not mixed use
Property Use 1 or 2 family dwelling
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 11 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 1 hour, 53 minutes

Response


Incident Type Building fires
Department Station HQ
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Alarms 0

Personnel


Support Personnel 2
EMS Personnel 0
Other Personnel 36

Fire Department


Name Avon Volunteer Fire Department, Inc.
Department Type Volunteer
Address 25 Darling Dr
Avon, CT 06001-4218
Phone (860) 677-2644
Website https://www.avonvfd.org/

Actions Taken


First Action Taken Extinguish
Second Action Taken Shut down system

Metadata


Incident Key CT_02010_07062017_0000295_0
State Connecticut
Fire Department ID 02010
Incident Date 07/06/2017
Incident Number 0000295
Exposure Number 0
NFIRS Version 5.0

Fire Report

Ignition


Area of Origin Laundry area, wash house (laundry)
Heat Source Undetermined
Item First Ignited Appliance housing or casing
Type of Material Undetermined
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Undetermined

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 2
Building Height: Stories Below Grade 0
Total Square Feet 960 sqft

Number of Stories With Damage


Story of Fire Origin 2
Number of Stories with Damage: Minor 1
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Acres Burned 0
Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Operation Operated
Detector Effectiveness Alerted Occupants

Equipment


Equipment Brand no
Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary
Sponsored