Report Icon

Incident Report – 08/07/2019
2 Squamscott Ave, Derry, NH 03038

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On August 7, 2019, Derry Fire Department responded to a fire incident at 2 Squamscott Ave, Derry, NH 03038, a 1-or-2 family dwelling.

The alarm was received at 6:22 PM, 12 suppression, 2 EMS, and 5 other personnel arrived at 6:28 PM, the incident was controlled at 7:04 PM, and the last unit was cleared at 9:33 PM. The time to arrive was 6 minutes, the time to control the incident was 36 minutes, and the total incident time was 3 hours, 11 minutes.

The following actions were taken during the incident: fire/other, search, and ventilate.

Sponsored

Location


Type Street address
Address 2 Squamscott Ave, Derry, NH 03038
County Rockingham County
State NH
City DERRY
Zip Code 03038
Property Use 1 or 2 family dwelling

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 6 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 36 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 3 hours, 11 minutes

Response


Incident Type Building fires
Department Station 02
Mutual Aid Given/Received Mutual aid received
Resources Include Mutual Aid No
Shift 3
Alarms 1
District 02

Personnel


Support Personnel 12
EMS Personnel 2
Other Personnel 5

Fire Department


Name Derry Fire Department
Department Type Career
Address 14 Manning St
Derry, NH 03038
Phone (603) 432-6121
Website https://www.derrynh.org/fire-department

Actions Taken


First Action Taken Fire, other
Second Action Taken Search
Third Action Taken Ventilate

Metadata


Incident Key NH_70814_08072019_0002998_0
State New Hampshire
Fire Department ID 70814
Incident Date 08/07/2019
Incident Number 0002998
Exposure Number 0
NFIRS Version 5.0

Fire Report

Cause


General Cause Natural
Main Fire Cause Natural

Ignition


Area of Origin Structural area, other
Heat Source Heat from direct flame, convection currents
Item First Ignited Structural component or finish, other
Type of Material Sawn wood, including all finished lumber
Cause of Ignition Act of nature
Factor Contributing To Ignition Storm
Factor Contributing To Ignition Electrical failure, malfunction, other

Spread


No Flame Spread/Same As First/Unknown Yes
Item Contributing Most To Spread Pipe, duct, conduit or hose
Type Material Contributing Most To Spread Wood or paper, processed, other

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 4
Building Height: Stories Below Grade 1
Total Square Feet 2418 sqft

Number of Stories With Damage


Story of Fire Origin 0
Number of Stories with Damage: Minor 2
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Suppression Factors


Suppression Factor Building construction or design factors, other

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Hardwire with battery
Detector Operation Operated
Detector Effectiveness Alerted Occupants
Sponsored