Incident Report – 10/26/2006 200 E 7th St, Washington, KS 66968
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On October 26, 2006, Washington City Volunteer Fire Department responded to a fire incident at 200 E 7th St, Washington, KS 66968, a convenience store.
The alarm was received at 12:14 PM, personnel arrived at 12:18 PM, and the last unit was cleared at 12:33 PM. The time to arrive was 4 minutes and the total incident time was 19 minutes.
The following actions were taken during the incident: fire/other and investigate.
Sponsored
Location
| Type | Street address |
| Address | 200 E 7th St, Washington, KS 66968 |
| County | Washington County |
| State | KS |
| City | Washington |
| Zip Code | 66968 |
| Property Use | Convenience store |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 4 minutes
Last unit cleared at
Alarm to last unit cleared: 19 minutes
Response
| Incident Type | Building fires |
| Department Station | 001 |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
| Alarms | 0 |
Fire Department
| Name | Washington City Volunteer Fire Department |
| Department Type | Volunteer |
| Address | 301 C St Washington, KS 66968-1908 |
| Phone | (785) 325-2159 |
Actions Taken
| First Action Taken | Fire, other |
| Second Action Taken | Investigate |
Metadata
| Incident Key | KS_WS301_10262006_0000011_0 |
| State | Kansas |
| Fire Department ID | WS301 |
| Incident Date | 10/26/2006 |
| Incident Number | 0000011 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
Fire Report
Ignition
| Area of Origin | Cooking area, kitchen |
| Heat Source | Arcing |
| Item First Ignited | Item First Ignited, Other |
| Confined To Origin | Fire Spread was Confined to Object of Origin |
| Type of Material | Undetermined |
| Cause of Ignition | Cause undetermined after investigation |
| Factor Contributing To Ignition | Unspecified short-circuit arc |
On-Site Materials
| On-Site Material | Deli products |
Spread
| No Flame Spread/Same As First/Unknown | No |
Structure
| Not Residential | Yes |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 1500 sqft |
| Number of Sprinklers Operating | 0 |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 0 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Acres Burned | 0 |
| Less Than One Acre | Yes |
Automatic Extinguishing System
| AES Presence | Undetermined |
Suppression Factors
| Suppression Factor | Electrical power outage |
Detector
| Detector Presence | Undetermined |
Mobile Property Involved
| Mobile Property Year | 0 |
Equipment
| Equipment Year | 0 |
Sponsored