Report Icon

Incident Report – 08/01/1994
200 S Jackson St, Mount Pleasant, IA 52641

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On August 1, 1994, a fire department near Mount Pleasant, IA responded to a fire incident at 200 S Jackson St, Mount Pleasant, IA 52641, a residential street/road or residential driveway.

The alarm was received at 6:53 PM and 12 suppression personnel arrived at 6:57 PM. The time to arrive was 4 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address 200 S Jackson St, Mount Pleasant, IA 52641
County Henry County
State IA
City Mount Pleasant
Zip Code 52641
Property Use Residential street, road or residential driveway

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 4 minutes

Response


Incident Type Mobile property (vehicle) fire, other
Mutual Aid Given/Received None
Alarms 1

Personnel


Support Personnel 12
EMS Personnel Unknown
Other Personnel Unknown

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key IA_44003_080194_000090_00
State Iowa
Fire Department ID 44003
Incident Date 08/01/1994
Incident Number 000090
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Electrical Dist

Legacy Fields


Estimated Dollar Loss 0
Day of Week Monday
Time In Service 19:30
Zip Code 52641
Method of Alarm Telephone direct to fire department
Type of Situation Found Vehicle fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 0
Complex Road complex
Fixed Property Use Paved private street, way
Mobile Property type General use small trucks under one ton weight
Area of Fire Origin Engine area, running gear, wheel area of transportation equipment
Level of Fire Origin Grade level to 9 feet above grade
Equipment Involved in Ignition Fixed wiring
Form of Heat of Ignition Arc from faulty contact, loose connection, broken conductor
Type of Material Ignited Plastic; insufficient information available to classify further
Form of Material Ignited Electrical wire, cable insulation
Ignition Factor Short circuit, ground fault
Method of Extinguishment Portable extinguisher
Property Damage Classification Undertermined
Occupancy Type Multiple occupancy
Occupancy Code EDUCATIONAL PROPERTY: UNCLASSIFIED

Fire Report

Ignition


Heat Source Arcing
Item First Ignited Electrical wire, cable insulation
Type of Material Plastic
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Arc from faulty contact, broken conductor

Number of Stories With Damage


Story of Fire Origin 83

Equipment


Equipment Power Electrical, other
Equipment Portability Unknown

Hazmat Report

Cause of Release


Cause of Release Container or containment failure

Equipment Involved in Release


Equipment

Equipment Model FIXED WIRING

Legacy Fields

Type of Situation Found Vehicle fire
Complex Road complex
Fixed Property Use Paved private street, way
Mobile Property Type General use small trucks under one ton weight
Area of Fire Origin Engine area, running gear, wheel area of transportation equipment
Equipment Involved in Ignition Fixed wiring
Form of Heat of Ignition Arc from faulty contact, loose connection, broken conductor
Type of Material Ignited Plastic; insufficient information available to classify further
Form of Material Ignited Electrical wire, cable insulation
Ignition Factor Short circuit, ground fault
Dollar Loss $0

Mobile Property


Description

Model 3 TON PICKUP
Year 86
License Plate HA3300

Legacy Fields

Make CHEVY
Serial Number 1GCBS1455G2194554
Type of Situation Found Vehicle fire
Complex Road complex
Fixed Property Use Paved private street, way
Mobile Property Type General use small trucks under one ton weight
Area of Fire Origin Engine area, running gear, wheel area of transportation equipment
Equipment Involved in Ignition Fixed wiring
Form of Heat of Ignition Arc from faulty contact, loose connection, broken conductor
Type of Material Ignited Plastic; insufficient information available to classify further
Form of Material Ignited Electrical wire, cable insulation
Ignition Factor Short circuit, ground fault
Time of Arrival 18:53
Dollar Loss $0
Sponsored