On February 2, 1996, a fire department near Hart, TX responded to a fire incident at 201 8th, Hart, TX 79043, a residential use, 1-or-2 family dwelling.

The alarm was received at 8:57 PM and 12 suppression personnel arrived at 8:57 PM.

The following action was taken during the incident: investigate.

Sponsored

Location


Address 201 8th, Hart, TX 79043
County Castro County
State TX
City Hart
Zip Code 79043
Mixed Use Residential use
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

Response


Incident Type Structure fire, other
Mutual Aid Given/Received None
Alarms 1
District 001

Personnel


Support Personnel 12
EMS Personnel Unknown
Other Personnel Unknown

Actions Taken


First Action Taken Investigate

Metadata


Incident Key TX_FM001_020296_964024_00
State Texas
Fire Department ID FM001
Incident Date 02/02/1996
Incident Number 964024
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Cooking

Legacy Fields


Estimated Dollar Loss 15,000
Day of Week Friday
Time In Service 23:00
Zip Code 79043
Method of Alarm Telephone tie-line to fire department
Type of Situation Found Structure fire
Type Action Taken Investigation only
Number of Aerial Apparatus 0
Complex Dwelling complex (one-and two-family)
Fixed Property Use One-family dwelling: year-round use
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Kitchen, cooking area
Level of Fire Origin Grade level to 9 feet above grade
Number of Stories 0
Equipment Involved in Ignition Fixed, stationary surface unit
Form of Heat of Ignition Heat from gas fueled equipment
Type of Material Ignited Natural gas
Form of Material Ignited Gas or liquid in or from pipe or container
Ignition Factor Part failure, leak, break
Construction Type Unprotected wood frame not qualifying for 7
Extent of Flame Damage Confined to room of origin
Extent of Smoke Damage No damage of this type
Form of Material Generating Most Smoke Exterior roof covering, surface, finish
Detector Performance No detectors present
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Natural gas
Avenue of Smoke Travel Most Significant Avenue of Smoke Travel not classified above
Method of Extinguishment Self-extinguished
Property Damage Classification 10,000-24,999 dollars
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING

Fire Report

Ignition


Heat Source Radiated, conducted heat from operating equipment
Item First Ignited Flammable liquid/gas in container or pipe
Type of Material Natural gas
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Leak or break

Structure


Number of Residential Units 1

Number of Stories With Damage


Story of Fire Origin 24

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Mobile Property Involved


Mobile Property Type Tank truck - nonflammable cargo

Equipment


Equipment Power Gas fuels, other
Equipment Portability Unknown