Report Icon

Incident Report – 12/04/2015
2015 Progress Dr, Springfield, OH 45503

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On December 4, 2015, Springfield City Fire Rescue Division responded to a fire incident at 2015 Progress Dr, Springfield, OH 45503, a mixed use or other use, warehouse.

The alarm was received at 8:03 PM, 5 suppression personnel arrived at 8:11 PM, and the last unit was cleared at 8:29 PM. The time to arrive was 8 minutes and the total incident time was 26 minutes.

The following actions were taken during the incident: incident command and investigate fire out on arrival.

Sponsored

Location


Type Street address
Address 2015 Progress Dr, Springfield, OH 45503
County Clark County
State OH
City Springfield
Zip Code 45503
Mixed Use Mixed use, other
Property Use Warehouse

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 8 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 26 minutes

Response


Incident Type Building fires
Department Station 6
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Shift C
Alarms 0
District 3

Personnel


Support Personnel 5
EMS Personnel 0
Other Personnel 0

Fire Department


Name Springfield City Fire Rescue Division
Department Type Career
Address 350 N Fountain Ave
Springfield, OH 45504-2537
Phone (937) 324-7605
Website https://springfieldohio.gov/springfield-services/fire-rescue/

Actions Taken


First Action Taken Incident command
Second Action Taken Investigate fire out on arrival

Losses *


Property Loss $10,000
Property Value $910,480
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key OH_12029_12042015_0016048_0
State Ohio
Fire Department ID 12029
Incident Date 12/04/2015
Incident Number 0016048
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Cause


General Cause Equipment
Main Fire Cause Equipment Misoperation, Failure
Priority Cause Equipment Failure, Malfunction

Ignition


Area of Origin Equipment or service area, other
Heat Source Heat source: other
Item First Ignited Undetermined
Confined To Origin Fire Spread was Confined to Object of Origin
Cause of Ignition Unintentional
Factor Contributing To Ignition Mechanical failure, malfunction, other

On-Site Materials


On-Site Material Metal products, other

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential Yes
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status Under construction
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Total Square Feet 27500 sqft
Number of Sprinklers Operating 0

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Acres Burned 0
Less Than One Acre No

Automatic Extinguishing System


AES Presence Present
AES Type Wet pipe sprinkler
AES Operation Failed to Operate
AES Failure Reason Undetermined

Detector


Detector Presence Detectors Present
Detector Type More than 1 type present
Detector Power Hardwire Only
Detector Operation Undetermined
Sponsored