On June 14, 1993, Garrison Fire Department responded to a fire incident at 204 E Pine St, Garrison, IA 52229, a residential use, 1-or-2 family dwelling.

The alarm was received at 7:48 AM and 16 suppression personnel arrived at 7:53 AM. The time to arrive was 5 minutes.

The following action was taken during the incident: investigate.

As a result of the incident, there were 2 other fire injuries.

Sponsored

Location


Address 204 E Pine St, Garrison, IA 52229
County Benton County
State IA
City Garrison
Zip Code 52229
Mixed Use Residential use
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 5 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received None

Personnel


Support Personnel 16
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name Garrison Fire Department
Department Type Volunteer
Address 205 N Sycamore
PO Box 247
Garrison, IA 52229-0247
Phone (319) 477-6102

Actions Taken


First Action Taken Investigate

Injuries/Deaths


Fire Service Injuries 0
Other Fire Injuries 2
Fire Service Deaths 0
Other Fire Deaths 0

Metadata


Incident Key IA_06004_061493_930019_00
State Iowa
Fire Department ID 06004
Incident Date 06/14/1993
Incident Number 930019
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Heating

Legacy Fields


Estimated Dollar Loss 2,000
Day of Week Monday
Zip Code 52229
Method of Alarm Telephone direct to fire department
Type of Situation Found Structure fire
Type Action Taken Investigation only
Number of Aerial Apparatus 0
Complex Dwelling complex (one-and two-family)
Fixed Property Use One-family dwelling: year-round use
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Duct
Level of Fire Origin Grade level to 9 feet above grade
Number of Stories 2
Equipment Involved in Ignition Fixed, stationary local heating unit
Form of Heat of Ignition Heat from gas fueled equipment
Type of Material Ignited Polyurethane
Form of Material Ignited Upholstered sofa, chair, vehicle seats
Ignition Factor Combustible too close to heat
Construction Type Unprotected wood frame not qualifying for 7
Extent of Flame Damage Confined to the object of origin
Extent of Smoke Damage Confined to structure or origin
Form of Material Generating Most Smoke Upholstered sofa, chair, vehicle seats
Detector Performance No detectors present
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Rubber
Avenue of Smoke Travel Stairwell
Method of Extinguishment Make-shift aids
Property Damage Classification 1,000-9,999 dollars
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING

Fire Report

Ignition


Heat Source Radiated, conducted heat from operating equipment
Item First Ignited Upholstered sofa, chair, vehicle seats
Type of Material Plastic
Cause of Ignition Unintentional
Factor Contributing To Ignition Heat source too close to combustibles

Structure


Number of Residential Units 1

Number of Stories With Damage


Story of Fire Origin 55

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Mobile Property Involved


Mobile Property Type Helicopter - nonmilitary

Equipment


Equipment Power Gas fuels, other
Equipment Portability Unknown

Civilian Casualty Report

Injured Person


Gender Male
Age 28
Affiliation Civilian

Severity


Severity Death

Cause of Injury


Cause of Injury Exposed to fire products

Activity When Injured


Activity When Injured Sleeping

Location


General Location At Time of Injury In building, but not in area of origin
Location At Time of Incident Not in area of origin but involved

Story


Story At Start of Incident 1

Legacy Fields


Birth Month 01
Birth Year 65
Time of Injury 748
Sex 1
Casualty Type Fire casualty
Severity Injury
Affiliation Civilian
Familiarity with Structure 7 to 12 months
Location at Ignition Fire casualty in same building as origin of fire
Condition Before Injury Asleep
Condition Preventing Escape Condition Preventing Escape undetermined or not reported
Activity at Time of Injury Sleeping
Cause of Injury Exposed to fire products. Included are flame, heat, smoke, and gas
Nature of Injury Asphyxia/smoke only
Part of Body Injured Internal. Included are respiratory system and heart
Disposition Treated at scene and released
Type Situation Found Structure fire
Complex Dwelling complex (one-and two-family)
Fixed Property Use One-family dwelling: year-round use
Mobile Property Type Mobile Property Type not applicable
Area of Fire Origin Duct
Equipment Involved in Ignition Fixed, stationary local heating unit
Form of Heat of Ignition Heat from gas fueled equipment
Type Material Ignited Polyurethane
Form of Material Ignited Upholstered sofa, chair, vehicle seats
Ignition Factor Combustible too close to heat
Alarm Time 0748
Day of Week 2
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING
Priority/Cause Grouping Code Heating
Priority/Cause Code Heating

Civilian Casualty Report

Injured Person


Gender Female
Age 28
Affiliation Civilian

Severity


Severity Death

Cause of Injury


Cause of Injury Exposed to fire products

Activity When Injured


Activity When Injured Sleeping

Location


General Location At Time of Injury In building, but not in area of origin
Location At Time of Incident Not in area of origin but involved

Story


Story At Start of Incident 1

Legacy Fields


Birth Month 06
Birth Year 65
Time of Injury 748
Sex 2
Casualty Type Fire casualty
Severity Injury
Affiliation Civilian
Familiarity with Structure 7 to 12 months
Location at Ignition Fire casualty in same building as origin of fire
Condition Before Injury Asleep
Condition Preventing Escape Condition Preventing Escape undetermined or not reported
Activity at Time of Injury Sleeping
Cause of Injury Exposed to fire products. Included are flame, heat, smoke, and gas
Nature of Injury Asphyxia/smoke only
Part of Body Injured Internal. Included are respiratory system and heart
Disposition Treated at scene and released
Type Situation Found Structure fire
Complex Dwelling complex (one-and two-family)
Fixed Property Use One-family dwelling: year-round use
Mobile Property Type Mobile Property Type not applicable
Area of Fire Origin Duct
Equipment Involved in Ignition Fixed, stationary local heating unit
Form of Heat of Ignition Heat from gas fueled equipment
Type Material Ignited Polyurethane
Form of Material Ignited Upholstered sofa, chair, vehicle seats
Ignition Factor Combustible too close to heat
Alarm Time 0748
Day of Week 2
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING
Priority/Cause Grouping Code Heating
Priority/Cause Code Heating
Sponsored