Summary


On January 12, 2021, Temple Fire & Rescue responded to a fire incident at 206 Beaver Loop, Temple, TX 76502, a 1-or-2 family dwelling.

The alarm was received at 1:24 PM, 3 suppression personnel arrived at 1:32 PM, and the last unit was cleared at 1:47 PM. The time to arrive was 8 minutes and the total incident time was 23 minutes.

The following action was taken during the incident: ventilate.

Sponsored

Location


Type Street address
Address 206 Beaver Loop, Temple, TX 76502
County Bell County
State TX
City Temple
Zip Code 76502
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Unknown
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 8 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 23 minutes

Response


Incident Type Fires in structures other than in a building
Department Station ST7
Mutual Aid Given/Received None
Resources Include Mutual Aid No

Personnel


Support Personnel 3
EMS Personnel 0
Other Personnel 0

Fire Department


Name Temple Fire & Rescue
Department Type Career
Address 210 N 3RD St
Temple, TX 76501-3102
Phone (254) 298-5682
Website https://www.templetx.gov/index.aspx?nid=123

Actions Taken


First Action Taken Ventilate

Metadata


Incident Key TX_AV612_01122021_461_0
State Texas
Fire Department ID AV612
Incident Date 01/12/2021
Incident Number 461
Exposure Number 0
NFIRS Version 5.0

Fire Report

Cause


General Cause Flame, Heat
Main Fire Cause Open Flame
Priority Cause Matches, Candles

Ignition


Area of Origin Bathroom, checkroom, lavatory, locker room
Heat Source Candle
Item First Ignited Wearing apparel not on a person
Type of Material Fabric, fiber, cotton, blends, rayon, wool
Cause of Ignition Unintentional
Factor Contributing To Ignition Heat source too close to combustibles

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Structure type, other
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Total Square Feet 1600 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Undetermined
Detector Operation Undetermined