Report Icon

Incident Report – 11/05/2021
21 Crestview Ter, Stratham, NH 03885

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On November 5, 2021, Stratham Volunteer Fire Department responded to a fire incident at 21 Crestview Ter, Stratham, NH 03885, a 1-or-2 family dwelling.

The alarm was received at 8:25 PM, 6 suppression and 3 EMS personnel arrived at 8:35 PM, the incident was controlled at 9:28 PM, and the last unit was cleared at 10:21 PM. The time to arrive was 10 minutes, the time to control the incident was 53 minutes, and the total incident time was 1 hour, 56 minutes.

The following actions were taken during the incident: fire/other and salvage and overhaul.

Sponsored

Location


Type Street address
Address 21 Crestview Ter, Stratham, NH 03885
County Rockingham County
State NH
City Stratham
Zip Code 03885
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Unknown
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 10 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 53 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 1 hour, 56 minutes

Response


Incident Type Building fires
Department Station 1
Mutual Aid Given/Received Automatic aid received
Resources Include Mutual Aid No

Personnel


Support Personnel 6
EMS Personnel 3
Other Personnel 0

Fire Department


Name Stratham Volunteer Fire Department
Department Type Volunteer
Address 10 Bunker Hill Ave
Stratham, NH 03885-2403
Phone (603) 772-9756

Actions Taken


First Action Taken Fire, other
Second Action Taken Salvage & overhaul

Metadata


Incident Key NH_73430_11052021_706_0
State New Hampshire
Fire Department ID 73430
Incident Date 11/05/2021
Incident Number 706
Exposure Number 0
NFIRS Version 5.0

Fire Report

Cause


General Cause Equipment
Main Fire Cause Appliances
Priority Cause Appliances

Ignition


Area of Origin Bedroom - < 5 persons; included are jail or prison
Heat Source Radiated, conducted heat from operating equipment
Item First Ignited Wearing apparel not on a person
Type of Material Fabric, fiber, cotton, blends, rayon, wool
Cause of Ignition Unintentional
Factor Contributing To Ignition Heat source too close to combustibles

Spread


No Flame Spread/Same As First/Unknown Yes
Item Contributing Most To Spread Soft goods, wearing apparel, other
Type Material Contributing Most To Spread Fabric, fiber, cotton, blends, rayon, wool

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 2
Building Height: Stories Below Grade 1
Building Length 40 ft
Building Width 20 ft

Number of Stories With Damage


Story of Fire Origin 2
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 1
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Hardwire with battery
Detector Operation Fire too small to operate

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Portable
Sponsored