Incident Report – 05/05/1998 210 E Comet Rd Colby, WI 54421
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On May 5, 1998, City of Green Fire Department responded to a fire incident at 210 E Comet Rd Colby, WI 54421, a residential use, parking garage (detached residential garage).
The alarm was received at 2:42 PM and 9 suppression personnel arrived at 2:49 PM. The time to arrive was 7 minutes.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Address | 210 E Comet Rd Colby, WI 54421 |
| County | Clark County |
| State | WI |
| City | Colby |
| Zip Code | 54421 |
| Mixed Use | Residential use |
| Property Use | Parking garage, (detached residential garage) |
| Census Tract | 000600 |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 7 minutes
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | None |
| Alarms | 1 |
Personnel
| Support Personnel | 9 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | City of Green Fire Department |
| Department Type | Career |
| Address | 4200 Massillon Rd North Canton, OH 44720-1140 |
| Phone | (330) 896-6610 |
| Website | https://www.cityofgreen.org/ |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | OH_77111_050598_872925_00 |
| State | Ohio |
| Fire Department ID | 77111 |
| Incident Date | 05/05/1998 |
| Incident Number | 872925 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Children Playing |
Legacy Fields
| Estimated Dollar Loss | 300 |
| Day of Week | Tuesday |
| Time In Service | 15:33 |
| Zip Code | 54421 |
| Method of Alarm | Telephone direct to fire department |
| Type of Situation Found | Structure fire |
| Type Action Taken | Extinguishment |
| Number of Aerial Apparatus | 0 |
| Complex | Dwelling complex (one-and two-family) |
| Fixed Property Use | Residential parking garage |
| Mobile Property type | Mobile Property Type not applicable |
| Area of Fire Origin | Exterior wall surface |
| Level of Fire Origin | Grade level to 9 feet above grade |
| Number of Stories | 1 |
| Equipment Involved in Ignition | No equipment involved |
| Form of Heat of Ignition | Match |
| Type of Material Ignited | Hardboard, plywood |
| Form of Material Ignited | Exterior sidewall covering, surface, finish |
| Ignition Factor | Children with, children playing |
| Construction Type | Unprotected wood frame not qualifying for 7 |
| Extent of Flame Damage | Confined to part of room or area of origin |
| Extent of Smoke Damage | Confined to floor of origin |
| Form of Material Generating Most Smoke | Structural Component, Finish; insufficient information available to classify further |
| Detector Performance | No detectors present |
| Sprinkler Performance | No equipment present in room or space of fire origin |
| Type of Material Generating Most Smoke | Sawn wood |
| Avenue of Smoke Travel | Utility opening in wall |
| Method of Extinguishment | Preconnected hose line(s) with water carried in apparatus tanks |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | OTHER RESIDENTIAL OCCUPANCIES |
Fire Report
Ignition
| Heat Source | Match |
| Item First Ignited | Exterior wall covering or finish |
| Type of Material | Plywood |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Playing with heat source |
Number of Stories With Damage
| Story of Fire Origin | 76 |
Human Factors Contributing to Ignition
| Human Factor | Age was a factor |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Mobile Property Involved
| Mobile Property Type | Aerial tramway vehicle |
Sponsored