Report Icon

Incident Report – 04/16/1989
210 Main, West Groton, MA 01472

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On April 16, 1989, Lexington Fire Department responded to a fire incident at 210 Main, West Groton, MA 01472, a residential use, 1-or-2 family dwelling.

The alarm was received at 1:57 PM and 15 suppression personnel arrived at 2:01 PM. The time to arrive was 4 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address 210 Main, West Groton, MA 01472
County Middlesex County
State MA
City West Groton
Zip Code 01472
Mixed Use Residential use
Property Use 1 or 2 family dwelling
Census Tract 007200
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 4 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received None
Alarms 2
District 002

Personnel


Support Personnel 15
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name Lexington Fire Department
Department Type Career
Address 45 Bedford St
Lexington, MA 02420-4339
Phone (781) 862-0272
Website https://www.lexingtonma.gov/fire-department

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key MA_17155_041689_890416_00
State Massachusetts
Fire Department ID 17155
Incident Date 04/16/1989
Incident Number 890416
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Suspicious

Legacy Fields


Estimated Dollar Loss 0
Day of Week Sunday
Time In Service 14:28
Zip Code 01472
Method of Alarm Telephone direct to fire department
Type of Situation Found Structure fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 0
Complex Dwelling complex (one-and two-family)
Fixed Property Use Two-family dwelling: year-round use
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Sleeping room for under 5 persons
Level of Fire Origin Grade level to 9 feet above grade
Number of Stories 1
Equipment Involved in Ignition No equipment involved
Form of Heat of Ignition Lighter (flame type)
Type of Material Ignited Cotton, rayon, cotton fabric, finished goods
Form of Material Ignited Mattress, pillow
Ignition Factor Incendiary, not during civil disturbance
Construction Type Unprotected wood frame not qualifying for 7
Extent of Flame Damage Confined to the object of origin
Extent of Smoke Damage Confined to structure or origin
Form of Material Generating Most Smoke Mattress, pillow
Detector Performance No detectors present
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Cotton, rayon, cotton fabric, finished goods
Avenue of Smoke Travel Stairwell
Method of Extinguishment Preconnected hose line(s) with water carried in apparatus tanks
Property Damage Classification Undertermined
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING

Fire Report

Ignition


Heat Source Cigarette lighter
Item First Ignited Mattress, pillow
Type of Material Fabric, fiber, cotton, blends, rayon, wool
Cause of Ignition Intentional

Structure


Number of Residential Units 2

Number of Stories With Damage


Story of Fire Origin 21

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Mobile Property Involved


Mobile Property Type General use truck, dump truck, fire apparatus
Sponsored