On December 3, 2022, Vernon Fire/EMS responded to a fire incident at 2110 Beaver St, Vernon, TX 76384, a 1-or-2 family dwelling.

The alarm was received at 3:44 PM, 5 suppression, 2 EMS, and 1 other personnel arrived at 3:50 PM, and the last unit was cleared at 5:21 PM. The time to arrive was 6 minutes and the total incident time was 1 hour, 37 minutes.

The following actions were taken during the incident: extinguish, salvage and overhaul, and investigate.

Sponsored

Location


Type Street address
Address 2110 Beaver St, Vernon, TX 76384
County Wilbarger County
State TX
City Vernon
Zip Code 76384
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Unknown
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 6 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 1 hour, 37 minutes

Response


Incident Type Building fires
Department Station 1
Mutual Aid Given/Received None
Resources Include Mutual Aid No

Personnel


Support Personnel 5
EMS Personnel 2
Other Personnel 1

Fire Department


Name Vernon Fire/EMS
Department Type Mostly career
Address 4109 Wilbarger St
Vernon, TX 76384-3137
Phone (940) 553-1782
Website https://www.vernontx.gov/

Actions Taken


First Action Taken Extinguish
Second Action Taken Salvage & overhaul
Third Action Taken Investigate

Metadata


Incident Key TX_XS603_12032022_1936_0
State Texas
Fire Department ID XS603
Incident Date 12/03/2022
Incident Number 1936
Exposure Number 0
NFIRS Version 5.0

Fire Report

Cause


General Cause Electrical
Main Fire Cause Electrical Malfunction
Priority Cause Electrical Dist

Ignition


Area of Origin Wall surface: exterior
Heat Source Arcing
Item First Ignited Exterior wall covering or finish
Type of Material Wood or paper, processed, other
Cause of Ignition Unintentional
Factor Contributing To Ignition Undetermined

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Total Square Feet 1000 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 1
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Undetermined

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary