On December 19, 2019, Syracuse Volunteer Fire Department responded to a fire incident at 214 5th St, Syracuse, NE 68446, a general retail property.

The alarm was received on 12/19/2019 at 10:37 PM, 23 suppression personnel arrived on 12/19/2019 at 10:39 PM, the incident was controlled on 12/19/2019 at 11:00 PM, and the last unit was cleared on 12/20/2019 at 12:15 AM. The time to control the incident was 21 minutes and the total incident time was 1 hour, 38 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Type Street address
Address 214 5th St, Syracuse, NE 68446
County Otoe County
State NE
City Syracuse
Zip Code 68446
Property Use General retail, other
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 21 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 1 hour, 38 minutes

Response


Incident Type Building fires
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Shift A
Alarms 1
District Cit

Personnel


Support Personnel 23
EMS Personnel 0
Other Personnel 0

Fire Department


Name Syracuse Volunteer Fire Department
Department Type Volunteer
Address 578 Mohawk St
PO Box 178
Syracuse, NE 68446
Phone (402) 269-2455

Actions Taken


First Action Taken Extinguish

Losses *


Property Loss $1,000
Contents Loss $0
Property Value $48,900
Contents Value $45,000
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key NE_11007_12192019_0000032_0
State Nebraska
Fire Department ID 11007
Incident Date 12/19/2019
Incident Number 0000032
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Cause


General Cause Electrical
Main Fire Cause Electrical Malfunction
Priority Cause Unclassified elec malfunction

Ignition


Area of Origin Wall surface: exterior
Heat Source Arcing
Item First Ignited Exterior wall covering or finish
Type of Material Sawn wood, including all finished lumber
Cause of Ignition Unintentional
Factor Contributing To Ignition Unspecified short-circuit arc

Spread


No Flame Spread/Same As First/Unknown Yes
Item Contributing Most To Spread Exterior wall covering or finish
Type Material Contributing Most To Spread Sawn wood, including all finished lumber

Structure


Not Residential Yes
Number of Buildings Involved 2
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Total Square Feet 2640 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 1
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present