Report Icon

Incident Report – 02/28/2021
2195 Wagon Wheel Rd, Ripton, VT 05766

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On February 28, 2021, Ripton Fire & Rescue responded to a fire incident at 2195 Wagon Wheel Rd, Ripton, VT 05766, a residential property.

The alarm was received at 8:27 PM, 6 suppression and 2 other personnel arrived at 8:50 PM, the incident was controlled at 9:20 PM, and the last unit was cleared at 9:20 PM. The time to arrive was 23 minutes, the time to control the incident was 30 minutes, and the total incident time was 53 minutes.

The following action was taken during the incident: investigate fire out on arrival.

Sponsored

Location


Type Street address
Address 2195 Wagon Wheel Rd, Ripton, VT 05766
County Addison County
State VT
City Ripton
Zip Code 05766
Property Use Residential, other
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 23 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 30 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 53 minutes

Response


Incident Type Building fires
Mutual Aid Given/Received Mutual aid received

Personnel


Support Personnel 6
EMS Personnel 0
Other Personnel 2

Fire Department


Name Ripton Fire & Rescue
Department Type Volunteer
Address 25 Dugway Rd
Ripton, VT 05766
Phone (802) 388-4506
Website https://www.riptonvermont.org/fire-rescue

Actions Taken


First Action Taken Investigate fire out on arrival

Losses *


Property Loss $500
Contents Loss $0
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key VT_01522_02282021_2021006_0
State Vermont
Fire Department ID 01522
Incident Date 02/28/2021
Incident Number 2021006
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Cause


General Cause Equipment
Main Fire Cause Heating
Priority Cause Heating

Ignition


Area of Origin Wall assembly
Heat Source Heat source: other
Item First Ignited Exterior wall covering or finish
Confined To Origin Fire Spread was Confined to Object of Origin
Type of Material Plywood
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Installation deficiency

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 2
Building Height: Stories Below Grade 0
Total Square Feet 1000 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 1

Acres


Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Undetermined

Equipment


Equipment Power Wood, paper
Equipment Portability Stationary
Sponsored