Incident Report – 02/02/2018 22061 Emerald Ave, West Grove, IA 52537
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On February 2, 2018, Bloomfield Volunteer Fire Department responded to a fire incident at 22061 Emerald Ave, West Grove, IA 52537, a 1-or-2 family dwelling.
The alarm was received at 3:35 PM, 6 suppression personnel arrived at 3:55 PM, the incident was controlled at 5:40 PM, and the last unit was cleared at 6:03 PM. The time to arrive was 20 minutes, the time to control the incident was 1 hour, 45 minutes, and the total incident time was 28 minutes.
The following actions were taken during the incident: fire/other and salvage and overhaul.
Sponsored
Location
| Type | Street address |
| Address | 22061 Emerald Ave, West Grove, IA 52537 |
| County | Davis County |
| State | IA |
| City | West Grove |
| Zip Code | 52537 |
| Property Use | 1 or 2 family dwelling |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 20 minutes
Incident controlled at
Alarm to incident controlled: 1 hour, 45 minutes
Last unit cleared at
Alarm to last unit cleared: 28 minutes
Response
| Incident Type | Building fires |
| Mutual Aid Given/Received | Automatic aid received |
| Resources Include Mutual Aid | No |
| District | Wes |
Personnel
| Support Personnel | 6 |
| EMS Personnel | 0 |
| Other Personnel | 0 |
Fire Department
| Name | Bloomfield Volunteer Fire Department |
| Department Type | Volunteer |
| Address | 501 S West St Bloomfield, IA 52537 |
| Phone | (641) 664-1147 |
Actions Taken
| First Action Taken | Fire, other |
| Second Action Taken | Salvage & overhaul |
Losses *
| Property Loss | $45,000 |
| Contents Loss | $55,000 |
| Property Value | $45,000 |
| Contents Value | $55,000 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | IA_26001_02022018_18674_0 |
| State | Iowa |
| Fire Department ID | 26001 |
| Incident Date | 02/02/2018 |
| Incident Number | 18674 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Ignition
| Area of Origin | Technical processing areas, other |
| Heat Source | Arcing |
| Item First Ignited | Electrical wire, cable insulation |
| Type of Material | Material compounded with oil, other |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Mechanical failure, malfunction, other |
On-Site Materials
| On-Site Material | Furnishings, other |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
Structure
| Not Residential | No |
| Number of Residential Units | 1 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 0 |
| Building Length | 45 ft |
| Building Width | 70 ft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
Acres
| Less Than One Acre | Yes |
Human Factors Contributing to Ignition
| Human Factor | Unattended or unsupervised person |
Automatic Extinguishing System
| AES Presence | None Present |
Suppression Factors
| Suppression Factor | Snow |
Detector
| Detector Presence | None Present |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Stationary |
Sponsored