Incident Report – 08/08/2022 23 Preble St, Gorham, ME 04038
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On August 8, 2022, Gorham Fire Department responded to a fire incident at 23 Preble St, Gorham, ME 04038, a boarding/rooming house/residential hotel.
The alarm was received at 7:37 PM, 4 suppression and 4 other personnel arrived at 7:40 PM, and the last unit was cleared at 8:07 PM. The time to arrive was 3 minutes and the total incident time was 30 minutes.
The following actions were taken during the incident: hazmat detection/monitoring/sampling/and analysis, provide air supply, and notify other agencies.
Sponsored
Location
| Type | Street address |
| Address | 23 Preble St, Gorham, ME 04038 |
| County | Cumberland County |
| State | ME |
| City | Gorham |
| Zip Code | 04038 |
| Property Use | Boarding/rooming house, residential hotels |
| Detector Alerted Occupants | Unknown |
| Hazardous Material Released | None |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 3 minutes
Last unit cleared at
Alarm to last unit cleared: 30 minutes
Response
| Incident Type | Fuel burner/boiler malfunction, fire confined |
| Department Station | D2 |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 4 |
| EMS Personnel | 0 |
| Other Personnel | 4 |
Fire Department
| Name | Gorham Fire Department |
| Department Type | Mostly volunteer |
| Address | 270 Main St Gorham, ME 04038-1312 |
| Phone | (207) 222-1660 |
| Website | https://www.gorham-me.org/fire-rescue-department |
Actions Taken
| First Action Taken | Hazmat detection, monitoring, sampling, & analysis |
| Second Action Taken | Provide air supply |
| Third Action Taken | Notify other agencies |
Metadata
| Incident Key | ME_C2500_08082022_1820_0 |
| State | Maine |
| Fire Department ID | C2500 |
| Incident Date | 08/08/2022 |
| Incident Number | 1820 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
Fire Report
Cause
| General Cause | Equipment |
| Main Fire Cause | Heating |
| Priority Cause | Heating |
Ignition
| Area of Origin | Heating room or area, water heater area |
| Heat Source | Heat from direct flame, convection currents |
| Item First Ignited | Flammable liquid/gas - in/from engine or burner |
| Confined To Origin | Fire Spread was Confined to Object of Origin |
| Type of Material | Kerosene, No.1 and 2 fuel oil, diesel type |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Backfire |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
Structure
| Not Residential | No |
| Number of Residential Units | 9 |
| Number of Buildings Involved | 0 |
Acres
| Less Than One Acre | Yes |
Sponsored