Report Icon

Incident Report – 03/20/2020
2309 N 9th St, Clinton, IA 52732

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On March 20, 2020, Clinton Fire Department responded to a fire incident at 2309 N 9th St, Clinton, IA 52732, a non-mixed use, 1-or-2 family dwelling.

The alarm was received at 6:14 PM, 13 suppression personnel arrived at 6:18 PM, and the last unit was cleared at 11:39 PM. The time to arrive was 4 minutes and the total incident time was 5 hours, 25 minutes.

The following actions were taken during the incident: extinguish, incident command, and investigate.

As a result of the incident, there were 2 fire service injuries.

Sponsored

Location


Type Street address
Address 2309 N 9th St, Clinton, IA 52732
County Clinton County
State IA
City Clinton
Zip Code 52732
Mixed Use Not mixed use
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Detector alerted occupants
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 4 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 5 hours, 25 minutes

Response


Incident Type Building fires
Department Station 001
Mutual Aid Given/Received Automatic aid received
Resources Include Mutual Aid No
Shift B
Alarms 3
District RD

Personnel


Support Personnel 13
EMS Personnel 0
Other Personnel 0

Fire Department


Name Clinton Fire Department
Department Type Career
Address 344 3rd AVE S
Clinton, IA 52732-4436
Phone (563) 242-0125
Website http://www.cityofclintoniowa.us/departments/fire/index.php

Actions Taken


First Action Taken Extinguish
Second Action Taken Incident command
Third Action Taken Investigate

Injuries/Deaths


Fire Service Injuries 2
Fire Service Deaths 0

Losses *


Property Loss $43,800
Contents Loss $15,000
Property Value $43,800
Contents Value $15,000
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key IA_23005_03202020_20983_0
State Iowa
Fire Department ID 23005
Incident Date 03/20/2020
Incident Number 20983
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Cause


General Cause Equipment
Main Fire Cause Appliances
Priority Cause Appliances

Ignition


Area of Origin Cooking area, kitchen
Heat Source Radiated, conducted heat from operating equipment
Item First Ignited Undetermined
Type of Material Material compounded with oil, other
Cause of Ignition Unintentional
Factor Contributing To Ignition Equipment unattended

Spread


No Flame Spread/Same As First/Unknown Yes
Item Contributing Most To Spread Structural member or framing
Type Material Contributing Most To Spread Sawn wood, including all finished lumber

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 1
Total Square Feet 1264 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 2
Number of Stories with Damage: Extreme 0

Acres


Acres Burned 0
Less Than One Acre No

Human Factors Contributing to Ignition


Human Factor Unattended or unsupervised person

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Battery Only
Detector Operation Operated
Detector Effectiveness Alerted Occupants

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary

Firefighter Casualty Report

Injured Person


Gender Male
Age 35
Career Career

Injury Date and Time


Injury Date and Time 03/20/2020 7:30 PM

Physical Condition


Physical Condition Undetermined

Severity


Severity Lost time injury, moderate severity

Taken To


Taken To Hospital

Activity At Time Of Injury


Activity At Time of Injury Using hand tools in extinguishment activity

Injury


Primary Apparent Symptom Cardiac symptoms
Primary Area of Body Injured Internal, other
Factor Contributing to Injury Fire development, other
Where Injury Occurred At scene, in structure
Injury Relation to Structure Inside/On Structure
Story of Injury 2
Specific Location On ground ladder
Protective Equipment Contributed to Injury No