On March 24, 1990, a fire department near Rhinelander, WI responded to a fire incident at 24 E Timber Dr, Rhinelander, WI 54501, a residential use, multifamily dwelling.

The alarm was received at 11:06 PM and 6 suppression personnel arrived at 11:08 PM.

The following action was taken during the incident: investigate.

Sponsored

Location


Address 24 E Timber Dr, Rhinelander, WI 54501
County Oneida County
State WI
City Rhinelander
Zip Code 54501
Mixed Use Residential use
Property Use Multifamily dwellings
Census Tract 009901
Detector Alerted Occupants Detector alerted occupants

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

Response


Incident Type Structure fire, other
Mutual Aid Given/Received None
Shift 2
Alarms 1

Personnel


Support Personnel 6
EMS Personnel Unknown
Other Personnel Unknown

Actions Taken


First Action Taken Investigate

Metadata


Incident Key WI_43011_032490_000172_00
State Wisconsin
Fire Department ID 43011
Incident Date 03/24/1990
Incident Number 000172
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Cooking

Legacy Fields


Estimated Dollar Loss 300
Day of Week Saturday
Time In Service 11:30
Zip Code 54501
Method of Alarm Telephone tie-line to fire department
Type of Situation Found Structure fire
Type Action Taken Investigation only
Number of Aerial Apparatus 0
Complex Apartment complex
Fixed Property Use 7 through 20 units
Area of Fire Origin Kitchen, cooking area
Level of Fire Origin Grade level to 9 feet above grade
Number of Stories 2
Equipment Involved in Ignition Fixed, stationary surface unit
Type of Material Ignited Grease (nonfood)
Form of Material Ignited Cabinetry
Ignition Factor Unattended
Construction Type Protected ordinary
Extent of Flame Damage Confined to the object of origin
Extent of Smoke Damage Confined to structure or origin
Form of Material Generating Most Smoke Type of Material not applicable
Detector Performance Detector(s) in the room or space of fire origin, and they operated
Sprinkler Performance No equipment present in room or space of fire origin
Avenue of Smoke Travel No significant avenue of smoke travel
Method of Extinguishment Self-extinguished
Property Damage Classification 100-999 dollars
Occupancy Type Single or double occupancy
Occupancy Code APARTMENTS, TENEMENTS, FLATS

Fire Report

Ignition


Item First Ignited Cabinetry (including built-in)
Type of Material Petroleum jelly and non-food grease
Cause of Ignition Unintentional
Factor Contributing To Ignition Equipment unattended

Structure


Number of Residential Units 12

Number of Stories With Damage


Story of Fire Origin 24

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Operation Operated
Detector Effectiveness Undetermined

Mobile Property Involved


Mobile Property Type Tank truck - nonflammable cargo