Summary
On March 30, 1995, Waco Fire Department responded to a fire incident at 2634 S 14th St, Waco, TX 76706, a residential use, 1-or-2 family dwelling.
The alarm was received at 9:32 PM and 3 suppression personnel arrived at 9:32 PM.
The following action was taken during the incident: investigate.
As a result of the incident, there were 2 other fire injuries.
Sponsored
Location
| Address | 2634 S 14th St, Waco, TX 76706 |
| County | McLennan County |
| State | TX |
| City | Waco |
| Zip Code | 76706 |
| Mixed Use | Residential use |
| Property Use | 1 or 2 family dwelling |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | None |
| Shift | B |
| Alarms | 1 |
| District | 004 |
Personnel
| Support Personnel | 3 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | Waco Fire Department |
| Department Type | Career |
| Address | 1016 Columbus Ave Waco, TX 76701-1243 |
| Phone | (254) 750-1740 |
| Website | https://www.waco-texas.com/Fire/index.asp |
Actions Taken
| First Action Taken | Investigate |
Injuries/Deaths
| Fire Service Injuries | 0 |
| Other Fire Injuries | 2 |
| Fire Service Deaths | 0 |
| Other Fire Deaths | 0 |
Metadata
| Incident Key | TX_RN726_033095_950745_00 |
| State | Texas |
| Fire Department ID | RN726 |
| Incident Date | 03/30/1995 |
| Incident Number | 950745 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Appliances |
Legacy Fields
| Estimated Dollar Loss | 75 |
| Day of Week | Thursday |
| Time In Service | 21:47 |
| Zip Code | 76706 |
| Method of Alarm | Telephone tie-line to fire department |
| Type of Situation Found | Structure fire |
| Type Action Taken | Investigation only |
| Number of Aerial Apparatus | 0 |
| Complex | Dwelling complex (one-and two-family) |
| Fixed Property Use | One-family dwelling: year-round use |
| Mobile Property type | Mobile Property Type not applicable |
| Area of Fire Origin | Kitchen, cooking area |
| Level of Fire Origin | Grade level to 9 feet above grade |
| Number of Stories | 0 |
| Equipment Involved in Ignition | Washing machine |
| Form of Heat of Ignition | Heat from overloaded equipment |
| Type of Material Ignited | Material Compounded with Oil; insufficient information available to classify further |
| Form of Material Ignited | Electrical wire, cable insulation |
| Ignition Factor | Misuse of Material ignited; insufficient information available to classify further |
| Construction Type | Protected Wood Frame |
| Extent of Flame Damage | Confined to the object of origin |
| Extent of Smoke Damage | No damage of this type |
| Form of Material Generating Most Smoke | Form of Material undetermined or not reported |
| Detector Performance | No detectors present |
| Sprinkler Performance | No equipment present in room or space of fire origin |
| Type of Material Generating Most Smoke | Material Compounded with Oil not classified above |
| Avenue of Smoke Travel | No significant avenue of smoke travel |
| Method of Extinguishment | Make-shift aids |
| Property Damage Classification | 1-99 dollars |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | ONE- AND TWO-FAMILY DWELLING |
Fire Report
Ignition
| Heat Source | Radiated, conducted heat from operating equipment |
| Item First Ignited | Electrical wire, cable insulation |
| Type of Material | Material compounded with oil, other |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Equipment overloaded |
Structure
| Number of Residential Units | 1 |
Number of Stories With Damage
| Story of Fire Origin | 24 |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Mobile Property Involved
| Mobile Property Type | Tank truck - nonflammable cargo |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Unknown |
Civilian Casualty Report
Injured Person
| Gender | Female |
| Age | 22 |
| Affiliation | Civilian |
Severity
| Severity | Death |
Cause of Injury
| Cause of Injury | Exposed to fire products |
Activity When Injured
| Activity When Injured | Unable to act |
Location
| General Location At Time of Injury | In area of origin |
| Location At Time of Incident | In area of origin and involved |
| Specific Location at Time of Injury | Cooking area, kitchen |
Story
| Story At Start of Incident | 1 |
| Story When Injury Occurred | 1 |
Disposition
| Disposition | Transported to emergency care facility |
Legacy Fields
| Birth Month | 01 |
| Birth Year | 73 |
| Time of Injury | 2132 |
| Sex | 2 |
| Casualty Type | Fire casualty |
| Severity | Injury |
| Affiliation | Civilian |
| Familiarity with Structure | 1 to 2 months |
| Location at Ignition | Fire casualty intimately involved with ignition |
| Condition Before Injury | Awake, unimpaired |
| Condition Preventing Escape | No time to escape; explosion or fire progressed too rapidly |
| Activity at Time of Injury | Unable to act |
| Cause of Injury | Exposed to fire products. Included are flame, heat, smoke, and gas |
| Nature of Injury | Burns only |
| Part of Body Injured | Multiple parts |
| Disposition | Taken to hospital by nonfire department vehicle |
| Type Situation Found | Structure fire |
| Complex | Dwelling complex (one-and two-family) |
| Fixed Property Use | One-family dwelling: year-round use |
| Mobile Property Type | Mobile Property Type not applicable |
| Area of Fire Origin | Kitchen, cooking area |
| Equipment Involved in Ignition | Washing machine |
| Form of Heat of Ignition | Heat from overloaded equipment |
| Type Material Ignited | Material Compounded with Oil; insufficient information available to classify further |
| Form of Material Ignited | Electrical wire, cable insulation |
| Ignition Factor | Misuse of Material ignited; insufficient information available to classify further |
| Alarm Time | 2132 |
| Day of Week | 5 |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | ONE- AND TWO-FAMILY DWELLING |
| Priority/Cause Grouping Code | Appliances |
| Priority/Cause Code | Appliances |
Civilian Casualty Report
Injured Person
| Gender | Female |
| Age | 3 |
| Affiliation | Civilian |
Severity
| Severity | Death |
Cause of Injury
| Cause of Injury | Exposed to fire products |
Activity When Injured
| Activity When Injured | Unable to act |
Location
| General Location At Time of Injury | In area of origin |
| Location At Time of Incident | In area of origin and involved |
| Specific Location at Time of Injury | Cooking area, kitchen |
Story
| Story At Start of Incident | 1 |
| Story When Injury Occurred | 1 |
Disposition
| Disposition | Transported to emergency care facility |
Legacy Fields
| Birth Month | 05 |
| Birth Year | 92 |
| Time of Injury | 2132 |
| Sex | 2 |
| Casualty Type | Fire casualty |
| Severity | Injury |
| Affiliation | Civilian |
| Familiarity with Structure | 1 to 2 months |
| Location at Ignition | Fire casualty intimately involved with ignition |
| Condition Before Injury | Awake, unimpaired |
| Condition Preventing Escape | No time to escape; explosion or fire progressed too rapidly |
| Activity at Time of Injury | Unable to act |
| Cause of Injury | Exposed to fire products. Included are flame, heat, smoke, and gas |
| Nature of Injury | Burns and asphyxia/smoke |
| Part of Body Injured | Multiple parts |
| Disposition | Taken to hospital by nonfire department vehicle |
| Type Situation Found | Structure fire |
| Complex | Dwelling complex (one-and two-family) |
| Fixed Property Use | One-family dwelling: year-round use |
| Mobile Property Type | Mobile Property Type not applicable |
| Area of Fire Origin | Kitchen, cooking area |
| Equipment Involved in Ignition | Washing machine |
| Form of Heat of Ignition | Heat from overloaded equipment |
| Type Material Ignited | Material Compounded with Oil; insufficient information available to classify further |
| Form of Material Ignited | Electrical wire, cable insulation |
| Ignition Factor | Misuse of Material ignited; insufficient information available to classify further |
| Alarm Time | 2132 |
| Day of Week | 5 |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | ONE- AND TWO-FAMILY DWELLING |
| Priority/Cause Grouping Code | Appliances |
| Priority/Cause Code | Appliances |
Sponsored