On November 6, 2022, Clinton City Fire/ Rescue responded to a fire incident at 2968 W 2025 N, Clinton, UT 84015, a 1-or-2 family dwelling.

The alarm was received at 9:31 PM, 2 suppression and 4 EMS personnel arrived at 9:35 PM, and the last unit was cleared at 9:56 PM. The time to arrive was 4 minutes and the total incident time was 25 minutes.

The following action was taken during the incident: investigate fire out on arrival.

Sponsored

Location


Type Street address
Address 2968 W 2025 N, Clinton, UT 84015
County Davis County
State UT
City Clinton
Zip Code 84015
Property Use 1 or 2 family dwelling
Census Tract 125500

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 4 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 25 minutes

Response


Incident Type Building fires
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Shift A

Personnel


Support Personnel 2
EMS Personnel 4
Other Personnel 0

Fire Department


Name Clinton City Fire/ Rescue
Department Type Mostly volunteer
Address 2153 N 1500 W
Clinton, UT 84015-8309
Phone (801) 614-0840
Website https://www.clintoncity.net/

Actions Taken


First Action Taken Investigate fire out on arrival

Losses *


Property Loss $2,000
Contents Loss $1
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key UT_11004_11062022_221500_0
State Utah
Fire Department ID 11004
Incident Date 11/06/2022
Incident Number 221500
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Cause


General Cause Electrical
Main Fire Cause Electrical Malfunction
Priority Cause Electrical Dist

Ignition


Area of Origin Wall surface: exterior
Heat Source Arcing
Item First Ignited Electrical wire, cable insulation
Confined To Origin Fire Spread was Confined to Object of Origin
Type of Material Plywood
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Short circuit arc from mechanical damage

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 1
Total Square Feet 1500 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 1
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary